EasyStep Human OC(Osteocalcin) ELISA Kit, 5 x 96 tests. For research use only.
Format
5 × 96 tests (5 plates of 96 wells)
Species
Human
Target
OC (Osteocalcin)
Type of dosage
ELISA sandwich
Sensitivity
0.14 ng/mL
Brand
ELK Biotechnology
Quantitative dosage ELISA Human d-OC sandwich (serum), result in 1.5 h.
This ELISA EasyStep ELK Biotechnology kit allows the quantitative in vitro determination of human OC (Osteocalcin) in the following samples: serum. The EasyStep range reduces the protocol to one step of incubation.
The assay is based on the ELISA sandwich technique: the microtitration plate is pre-coatted with a specific antibody d-OC. Standards or samples are added, followed by a detection antibody conjugated with peroxidase (HRP), in one step. After addition of the TMB substrate and cessation of the sulfuric acid reaction, the optical density is measured at 450 nm ± 10 nm; the concentration is determined using the standard curve.
Research-only product (RUO), not intended for diagnosis.
Sensitivity
Sensitivity of 0.14 ng/mL.
Range of dosage
The range of the assays is 0.23 to 15 ng/mL (highest standard: 15 ng/mL).
Samples
Serum.
Rapidity
Result in 1.5 h, protocol in one step.
Specificity
Sandwich format, human d-OC specific antibodies.
Reproducibility
Intra-test accuracy CV < 8%, inter-test CV < 10%.
Technical specifications
General
Brand
ELK Biotechnology
Range
EasyStep
Specifications
Format
5 × 96 tests (5 plates of 96 wells)
Species
Human
Target
OC (Osteocalcin)
Type of dosage
ELISA sandwich
Performance
Sensitivity
0.14 ng/mL
Range of dosage
0.23 – 15 ng/mL
Standard (maximum concentration)
15 ng/mL
Duration of dosing
1.5 h
Readability wave length
450 nm ± 10 nm
Specifications
Samples
Serum
Research area
Metabolic pathways, Endocrinology, Hormonal metabolism, Bone metabolism
Alternative names
BGLAP; OT; BGP; Bone Gla Protein; Bone Gamma-Carboxyglutamate Protein; Gamma-carboxyglutamic acid-containing protein
UniProt
P02818
Storage and shipping
Shipping
With ice loaves, without carboglace
Compliance
Use
research use only (RUO)
Validation
Intra-test accuracy
CV < 8 %
Inter-test accuracy
CV < 10 %
Standard curve (example)
15.00 ng/mL : DO 2.126; 7.50 ng/mL : DO 1.572; 3.75 ng/mL : DO 1.116; 1.88 ng/mL : DO 0.861; 0.94 ng/mL : DO 0.538; 0.47 ng/mL : DO 0.329; 0.24 ng/mL : DO 0.192; 0.00 ng/mL : DO 0.101
Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account. Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration? Contact us for a quote.