Human CA11(Carbonic Anhydrase 11) ELISA Kit, 5 x 96 tests. For research use only.
Format
5 × 96 tests (5 plates of 96 wells)
Species
Human
Target
CA11 (Carbonic Anhydrase 11)
Type of dosage
ELISA sandwich
Sensitivity
0.089 ng/mL
Brand
ELK Biotechnology
Quantitative dosage ELISA human CA11 sandwich (serum, plasma, saliva, other biological fluids), result in 3.5 h.
This ELISA ELK Biotechnology kit allows the quantitative in vitro assay of human CA11 (Carbonic Anhydrase 11) in the following samples: serum, plasma, saliva and other biological fluids.
The assay is based on the ELISA sandwich technique: the microtitration plate is pre-coatted with a specific antibody of CA11. Standards or samples are added, followed by a biotinylated and l-avidine detection antibody coupled with peroxidase (HRP). After addition of the TMB substrate and cessation of the sulfuric acid reaction, the optical density is measured at 450 nm ± 10 nm; the concentration is determined using the standard curve.
Research-only product (RUO), not intended for diagnosis.
Sensitivity
Sensitivity of 0.089 ng/mL.
Range of dosage
The range of the assays is 0.32 to 20 ng/mL (highest standard: 20 ng/mL).
Samples
Serum, plasma, saliva and other biological fluids.
Rapidity
Result in 3.5 hours.
Specificity
Sandwich format, specific antibodies of human CA11.
Reproducibility
Intra-test accuracy CV < 8%, inter-test CV < 10%.
Technical specifications
General
Brand
ELK Biotechnology
Range
Standard
Specifications
Format
5 × 96 tests (5 plates of 96 wells)
Species
Human
Target
CA11 (Carbonic Anhydrase 11)
Type of dosage
ELISA sandwich
Performance
Sensitivity
0.089 ng/mL
Range of dosage
0.32 – 20 ng/mL
Standard (maximum concentration)
20 ng/mL
Duration of dosing
3.5 h
Readability wave length
450 nm ± 10 nm
Specifications
Samples
Serum, plasma, saliva and other biological fluids
Research area
Enzymes and kinases
Alternative names
Carbonic anhydrase-related protein 11; CAH11; CA-RP XI; CA-XI; CARP XI; Carbonic anhydrase-related protein 2; CA-RP II; CARP-2
UniProt
O75493
Storage and shipping
Shipping
With ice loaves, without carboglace
Compliance
Use
research use only (RUO)
Validation
Intra-test accuracy
CV < 8 %
Inter-test accuracy
CV < 10 %
Standard curve (example)
20.00 ng/mL : DO 2.052; 10.00 ng/mL : DO 1.579; 5.00 ng/mL : DO 1.142; 2.50 ng/mL : DO 0.836; 1.25 ng/mL : DO 0.539; 0.63 ng/mL : DO 0.315; 0.32 ng/mL : DO 0.215; 0.00 ng/mL : DO 0.088
Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account. Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration? Contact us for a quote.