Human FliC(Flagellin) ELISA Kit – 5 x 96 tests

Ref.: BL-RE-950551Manufacturer ref.: ELK0116-5x96T 5 × 96 tests
€2,659.00 excl. VAT

Human FliC(Flagellin) ELISA Kit, 5 x 96 tests. For research use only.

Format
5 × 96 tests (5 plates of 96 wells)
Species
Human
Target
FliC (Flagellin)
Type of dosage
ELISA sandwich
Sensitivity
0.18 ng/mL
Brand
ELK Biotechnology

Quantitative ELISA Human FliC sandwich (serum, plasma, tissue homogenates, cellular lysates), result in 3.5 h.

This ELISA ELK Biotechnology kit allows the quantitative in vitro assay of human FliC (Flagellin) in the following samples: serum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids.

The assay is based on the ELISA sandwich technique: the microtitration plate is pre-coatted with a specific antibody of FliC. Standards or samples are added, followed by a biotinylated and l-avidine detection antibody coupled with peroxidase (HRP). After addition of the TMB substrate and cessation of the sulfuric acid reaction, the optical density is measured at 450 nm ± 10 nm; the concentration is determined using the standard curve.

Research-only product (RUO), not intended for diagnosis.

Sensitivity

Sensitivity of 0.18 ng/mL.

Range of dosage

Measurement range 0.79 to 50 ng/mL (highest standard 50 ng/mL).

Samples

Serum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids.

Rapidity

Result in 3.5 hours.

Specificity

Sandwich format, human FliC specific antibodies.

Reproducibility

Intra-test accuracy CV < 8%, inter-test CV < 10%.

Technical specifications

General
BrandELK Biotechnology
RangeStandard
Specifications
Format5 × 96 tests (5 plates of 96 wells)
SpeciesHuman
TargetFliC (Flagellin)
Type of dosageELISA sandwich
Performance
Sensitivity0.18 ng/mL
Range of dosage0.79 – 50 ng/mL
Standard (maximum concentration)50 ng/mL
Duration of dosing3.5 h
Readability wave length450 nm ± 10 nm
Specifications
SamplesSerum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids
Research areaGastroenterology
Alternative namesFliC
Storage and shipping
ShippingWith ice loaves, without carboglace
Compliance
Useresearch use only (RUO)
Validation
Intra-test accuracyCV < 8 %
Inter-test accuracyCV < 10 %
Standard curve (example)50.00 ng/mL : DO 2.082; 25.00 ng/mL : DO 1.709; 12.50 ng/mL : DO 0.980; 6.25 ng/mL : DO 0.797; 3.13 ng/mL : DO 0.519; 1.57 ng/mL : DO 0.218; 0.79 ng/mL : DO 0.241; 0.00 ng/mL : DO 0.095
Recovery (doped samples)serum (n=5): 83-95% (average 89%); EDTA plasma (n=5): 85-97% (average 91%); heparin plasma (n=5): 81-95% (average 88%)
Linearity (dilutions)serum (n=5): 1:2 91-99%, 1:4 88-97%, 1:8 88-104%, 1:16 97-108%; EDTA plasma (n=5): 1:2 93-102%, 1:4 86-92%, 1:8 96-105%, 1:16 89-97%; heparin plasma (n=5): 1:2 90-103%, 1:4 97-106%, 1:8 82-90%, 1:16 92-101%
Conservation
Storage of kitKit not open: 2-8 °C for 6 months, or -20 °C for 1 year; avoid freeze-thaw cycles.
Safety data sheetDownloadable with a B-LABO account

Origin and customs

Manufacturer ref.ELK0116-5x96T
Country of originChina
HS customs code3822 19 00 00

Scope of delivery

  • 5 kits of 96 tests, each containing:
  • Pre-coated microplate: 12 strips × 8 wells (conservation 4 °C or -20 °C)
  • Standard lyophilized: 2 vials (storage 4 °C or -20 °C)
  • Biotinylated detection antibody (100×): 120 μL (storage 4°C or -20°C)
  • Streptavidine-HRP (100×): 120 μL (storage 4 °C or -20 °C)
  • Standard dilution stamp/samples: 20 mL (storage 4 °C or -20 °C)
  • Biotinyl antibody diluent: 12 mL (storage 4 °C or -20 °C)
  • HRP diluent: 12 mL (storage 4 °C or -20 °C)
  • Wash pad (25×): 20 mL (storage 4°C or -20°C)
  • TMB substrate solution: 10 mL (storage 4°C or -20°C (in the shelter of light))
  • Stop solution: 6 mL (storage 4 °C or -20 °C)
  • Adhesive film for plate: 2 pieces (storage of room temperature)

Documentation

Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account.
Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration?
Contact us for a quote.