Human NLRP12(NACHT, LRR and PYD Domains-Containing Protein 12) ELISA Kit – 48 tests

Ref.: BL-RE-950669Manufacturer ref.: ELK0142-48T 48 tests
€437.00 excl. VAT

Human NLRP12(NACHT, LRR and PYD Domains-Containing Protein 12) ELISA Kit, 48 tests. For research use only.

Format
48 tests (1 plate of 48 wells)
Species
Human
Target
NLRP12 (NACHT, LRR and PYD Domains-Containing Protein 12)
Type of dosage
ELISA sandwich
Sensitivity
21.2 pg/mL
Brand
ELK Biotechnology

Quantitative ELISA Human NLRP12 sandwich (serum, plasma, other biological fluids), result in 3.5 h.

This ELISA ELK Biotechnology kit allows in vitro quantitative determination of NLRP12 (NACHT, LRR and PYD Domains-Containing Protein 12) in the following samples: serum, plasma and other biological fluids.

The assay is based on the ELISA sandwich technique: the microtitration plate is pre-coatted with a specific antibody of NLRP12. Standards or samples are added, followed by a biotinylated and l-avidine detection antibody coupled with peroxidase (HRP). After addition of the TMB substrate and cessation of the sulfuric acid reaction, the optical density is measured at 450 nm ± 10 nm; the concentration is determined using the standard curve.

Research-only product (RUO), not intended for diagnosis.

Sensitivity

Sensitivity of 21.2 pg/mL.

Range of dosage

The range of the assay is 78.13 to 5000 pg/mL (highest standard: 5000 pg/mL).

Samples

Serum, plasma and other biological fluids.

Rapidity

Result in 3.5 hours.

Specificity

Sandwich format, NLRP12 human specific antibodies.

Reproducibility

Intra-test accuracy CV < 8%, inter-test CV < 10%.

Technical specifications

General
BrandELK Biotechnology
RangeStandard
Specifications
Format48 tests (1 plate of 48 wells)
SpeciesHuman
TargetNLRP12 (NACHT, LRR and PYD Domains-Containing Protein 12)
Type of dosageELISA sandwich
Performance
Sensitivity21.2 pg/mL
Range of dosage78.13 – 5000 pg/mL
Standard (maximum concentration)5000 pg/mL
Duration of dosing3.5 h
Readability wave length450 nm ± 10 nm
Specifications
SamplesSerum, plasma and other biological fluids
Research areaSignal transduction
Alternative namesRNO; PAN6; RNO2; FCAS2; NALP12; PYPAF7; CLR19.3
UniProtP59046
Storage and shipping
ShippingWith ice loaves, without carboglace
Compliance
Useresearch use only (RUO)
Validation
Intra-test accuracyCV < 8 %
Inter-test accuracyCV < 10 %
Standard curve (example)5000.00 pg/mL : DO 2.041; 2500.00 pg/mL : DO 1.621; 1250.00 pg/mL : DO 1.285; 625.00 pg/mL : DO 0.876; 312.50 pg/mL : DO 0.511; 156.25 pg/mL : DO 0.286; 78.13 pg/mL : DO 0.206; 0.00 pg/mL : DO 0.089
Recovery (doped samples)serum (n=5): 80-98% (average 89%); EDTA plasma (n=5): 82-94% (average 88%); heparin plasma (n=5): 84-98% (average 91%)
Linearity (dilutions)serum (n=5): 1:2 89-99 %, 1:4 83-99 %, 1:8 98-105%, 1:16 96-101%; EDTA plasma (n=5): 1:2 95-103%, 1:4 91-105%, 1:8 78-90%, 1:16 89-97%; heparin plasma (n=5): 1:2 85-94%, 1:4 87-96 %, 1:8 82-93%, 1:16 89-103%
Conservation
Storage of kitKit not open: 2-8 °C for 6 months, or -20 °C for 1 year; avoid freeze-thaw cycles.
Safety data sheetDownloadable with a B-LABO account

Origin and customs

Manufacturer ref.ELK0142-48T
Country of originChina
HS customs code3822 19 00 00

Scope of delivery

  • Pre-coated microplate: 6 strips × 8 wells (conservation 4 °C or -20 °C)
  • Standard lyophilized: 1 vial (storage 4 °C or -20 °C)
  • Biotinylated detection antibody (100×): 60 μL (storage 4 °C or -20 °C)
  • Streptavidine-HRP (100×): 60 μL (storage 4 °C or -20 °C)
  • Standard dilution stamp/samples: 10 mL (storage 4 °C or -20 °C)
  • Biotinyl antibody diluent: 6 mL (storage 4 °C or -20 °C)
  • HRP diluent: 6 mL (storage 4 °C or -20 °C)
  • Wash pad (25×): 10 mL (storage 4°C or -20°C)
  • TMB substrate solution: 6 mL (storage 4 °C or -20 °C (in the shelter of light))
  • Stopping solution: 3 mL (storage 4 °C or -20 °C)
  • Adhesive film for plate: 1 piece (storage of room temperature)

Documentation

Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account.
Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration?
Contact us for a quote.