Human ACV-A(Activin A) ELISA Kit – 5 x 96 tests

Ref.: BL-RE-950807Manufacturer ref.: ELK0174-5x96T 5 × 96 tests
€2,659.00 excl. VAT

Human ACV-A(Activin A) ELISA Kit, 5 x 96 tests. For research use only.

Format
5 × 96 tests (5 plates of 96 wells)
Species
Human
Target
ACV-A (Activin A)
Type of dosage
ELISA sandwich
Sensitivity
4.71 pg/mL
Brand
ELK Biotechnology

Quantitative dosage ELISA human d-ACV-A sandwich (serum, plasma, tissue homogenates, cell lysates), result in 3.5 h.

This ELISA ELK Biotechnology kit allows the quantitative in vitro assay of human ACV-A (Activin A) in the following samples: serum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids.

The assay is based on the ELISA sandwich technique: the microtitration plate is pre-coatted with a specific antibody d-ACV-A. Standards or samples are added, followed by a biotinylated and l-avidine detection antibody coupled with peroxidase (HRP). After addition of the TMB substrate and cessation of the sulfuric acid reaction, the optical density is measured at 450 nm ± 10 nm; the concentration is determined using the standard curve.

Research-only product (RUO), not intended for diagnosis.

Sensitivity

Sensitivity of 4.71 pg/mL.

Range of dosage

The range of dosages from 15.63 to 1000 pg/mL (highest standard: 1000 pg/mL).

Samples

Serum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids.

Rapidity

Result in 3.5 hours.

Specificity

Sandwich format, human-specific anti-ACV-A antibodies.

Reproducibility

Intra-test accuracy CV < 8%, inter-test CV < 10%.

Technical specifications

General
BrandELK Biotechnology
RangeStandard
Specifications
Format5 × 96 tests (5 plates of 96 wells)
SpeciesHuman
TargetACV-A (Activin A)
Type of dosageELISA sandwich
Performance
Sensitivity4.71 pg/mL
Range of dosage15.63 – 1000 pg/mL
Standard (maximum concentration)1000 pg/mL
Duration of dosing3.5 h
Readability wave length450 nm ± 10 nm
Specifications
SamplesSerum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids
Research areaEndocrinology, Reproduction, Hormonal Metabolism
Alternative namesACVA; Activin Beta A Beta A Homodimer
Storage and shipping
ShippingWith ice loaves, without carboglace
Compliance
Useresearch use only (RUO)
Validation
Intra-test accuracyCV < 8 %
Inter-test accuracyCV < 10 %
Standard curve (example)1000.00 pg/mL : DO 2.274; 500.00 pg/mL : DO 1.527; 250.00 pg/mL : DO 1.034; 125.00 pg/mL : DO 0.841; 62.50 pg/mL : DO 0.521; 31.25 pg/mL : DO 0.364; 15.63 pg/mL : DO 0.146; 0.00 pg/mL : DO 0.105
Recovery (doped samples)serum (n=5): 92-107% (mean 99%); EDTA plasma (n=5): 87-99% (mean 93%); heparin plasma (n=5): 78-92% (mean 85%)
Linearity (dilutions)serum (n=5): 1:2 88-96 %, 1:4 86-95 %, 1:8 90-103%, 1:16 87-90%; EDTA plasma (n=5): 1:2 92-102%, 1:4 81-93%, 1:8 86-98%, 1:16 91-103%; heparin plasma (n=5): 1:2 85-97%, 1:4 87-96 %, 1:8 85-96 %, 1:16 85-95 %
Conservation
Storage of kitKit not open: 2-8 °C for 6 months, or -20 °C for 1 year; avoid freeze-thaw cycles.
Safety data sheetDownloadable with a B-LABO account

Origin and customs

Manufacturer ref.ELK0174-5x96T
Country of originChina
HS customs code3822 19 00 00

Scope of delivery

  • 5 kits of 96 tests, each containing:
  • Pre-coated microplate: 12 strips × 8 wells (conservation 4 °C or -20 °C)
  • Standard lyophilized: 2 vials (storage 4 °C or -20 °C)
  • Biotinylated detection antibody (100×): 120 μL (storage 4°C or -20°C)
  • Streptavidine-HRP (100×): 120 μL (storage 4 °C or -20 °C)
  • Standard dilution stamp/samples: 20 mL (storage 4 °C or -20 °C)
  • Biotinyl antibody diluent: 12 mL (storage 4 °C or -20 °C)
  • HRP diluent: 12 mL (storage 4 °C or -20 °C)
  • Wash pad (25×): 20 mL (storage 4°C or -20°C)
  • TMB substrate solution: 10 mL (storage 4°C or -20°C (in the shelter of light))
  • Stop solution: 6 mL (storage 4 °C or -20 °C)
  • Adhesive film for plate: 2 pieces (storage of room temperature)

Documentation

Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account.
Customers who have ordered: the SDS is attached automatically to the order confirmation.