EasyStep Human EFNA1(Ephrin A1) ELISA Kit, 96 tests. For research use only.
Format
96 tests (1 plate of 96 wells)
Species
Human
Target
EFNA1 (Ephrin A1)
Type of dosage
ELISA sandwich
Sensitivity
22.5 pg/mL
Brand
ELK Biotechnology
Quantitative dosage ELISA sandwich d'EFNA1 human (serum, plasma), result in 1.5 h.
This ELISA EasyStep ELK Biotechnology kit allows in vitro quantitative assays of human EFNA1 (Ephrin A1) in the following samples: serum and plasma. The EasyStep range reduces the protocol to one step of incubation.
The assay is based on the ELISA sandwich technique: the microtitration plate is pre-coatted with a specific antibody d-EFNA1. Standards or samples are added, followed by a detection antibody conjugated with peroxidase (HRP), in one step. After addition of the TMB substrate and cessation of the sulfuric acid reaction, the optical density is measured at 450 nm ± 10 nm; the concentration is determined using the standard curve.
Research-only product (RUO), not intended for diagnosis.
Sensitivity
Sensitivity of 22.5 pg/mL.
Range of dosage
Test range 0.16 to 10 ng/mL (highest standard: 10 ng/mL).
Samples
Serum and plasma.
Rapidity
Result in 1.5 h, protocol in one step.
Specificity
Sandwich format, human EFNA1 specific antibodies.
Reproducibility
Intra-test accuracy CV < 8%, inter-test CV < 10%.
Technical specifications
General
Brand
ELK Biotechnology
Range
EasyStep
Specifications
Format
96 tests (1 plate of 96 wells)
Species
Human
Target
EFNA1 (Ephrin A1)
Type of dosage
ELISA sandwich
Performance
Sensitivity
22.5 pg/mL
Range of dosage
0.16 – 10 ng/mL
Standard (maximum concentration)
10 ng/mL
Duration of dosing
1.5 h
Readability wave length
450 nm ± 10 nm
Specifications
Samples
Serum and plasma
Research area
Neuroscience
Alternative names
B61; ECKLG; EFL1; EPLG1; LERK1; TNFAIP4; EPH-related receptor tyrosine kinase ligand 1; Tumor necrosis factor alpha-induced protein 4; Immediate early response to B61
UniProt
P20827
Storage and shipping
Shipping
With ice loaves, without carboglace
Compliance
Use
research use only (RUO)
Validation
Intra-test accuracy
CV < 8 %
Inter-test accuracy
CV < 10 %
Standard curve (example)
10.00 ng/mL : DO 2.204; 5.00 ng/mL : DO 1.593; 2.50 ng/mL : DO 1.175; 1.25 ng/mL : DO 0.895; 0.63 ng/mL : DO 0.521; 0.32 ng/mL : DO 0.366; 0.16 ng/mL : DO 0.302; 0.00 ng/mL : DO 0.087
Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account. Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration? Contact us for a quote.