EasyStep Human VASP(Vasodilator Stimulated Phosphoprotein) ELISA Kit, 5 x 96 tests. For research use only.
Format
5 × 96 tests (5 plates of 96 wells)
Species
Human
Target
VASP (Vasodilator Stimulated Phosphoprotein)
Type of dosage
ELISA sandwich
Sensitivity
17.5 pg/mL
Brand
ELK Biotechnology
Quantitative ELISA human VASP sandwich (serum, plasma), result in 1.5 h.
This ELISA EasyStep ELK Biotechnology kit allows the in vitro quantitative determination of human VASP (Vasodilator Stimulated Phosphoprotein) in the following samples: serum and plasma. The EasyStep range reduces the protocol to one step of incubation.
The assay is based on the ELISA sandwich technique: the microtitration plate is pre-coatted with a specific antibody of VASP. Standards or samples are added, followed by a detection antibody conjugated with peroxidase (HRP), in one step. After addition of the TMB substrate and cessation of the sulfuric acid reaction, the optical density is measured at 450 nm ± 10 nm; the concentration is determined using the standard curve.
Research-only product (RUO), not intended for diagnosis.
Sensitivity
Sensitivity of 17.5 pg/mL.
Range of dosage
Test range 0.16 to 10 ng/mL (highest standard: 10 ng/mL).
Samples
Serum and plasma.
Rapidity
Result in 1.5 h, protocol in one step.
Specificity
Sandwich format, human VASP specific antibodies.
Reproducibility
Intra-test accuracy CV < 8%, inter-test CV < 10%.
Technical specifications
General
Brand
ELK Biotechnology
Range
EasyStep
Specifications
Format
5 × 96 tests (5 plates of 96 wells)
Species
Human
Target
VASP (Vasodilator Stimulated Phosphoprotein)
Type of dosage
ELISA sandwich
Performance
Sensitivity
17.5 pg/mL
Range of dosage
0.16 – 10 ng/mL
Standard (maximum concentration)
10 ng/mL
Duration of dosing
1.5 h
Readability wave length
450 nm ± 10 nm
Specifications
Samples
Serum and plasma
Research area
Signal transduction
Alternative names
Vasodilator-stimulated phosphoprotein
UniProt
P50552
Storage and shipping
Shipping
With ice loaves, without carboglace
Compliance
Use
research use only (RUO)
Validation
Intra-test accuracy
CV < 8 %
Inter-test accuracy
CV < 10 %
Standard curve (example)
10.00 ng/mL : DO 2.201; 5.00 ng/mL : DO 1.587; 2.50 ng/mL : DO 1.073; 1.25 ng/mL : DO 0.757; 0.63 ng/mL : DO 0.468; 0.32 ng/mL : DO 0.397; 0.16 ng/mL : DO 0.208; 0.00 ng/mL : DO 0.153
Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account. Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration? Contact us for a quote.