Human HNE(4-Hydroxynonenal) ELISA Kit – 48 tests

Ref.: BL-RE-950533Manufacturer ref.: ELK0114-48T 48 tests
€437.00 excl. VAT

Human HNE(4-Hydroxynonenal) ELISA Kit, 48 tests. For research use only.

Format
48 tests (1 plate of 48 wells)
Species
Human
Target
HNE (4-Hydroxynonenal)
Type of dosage
ELISA sandwich
Sensitivity
1.21 ng/mL
Brand
ELK Biotechnology

Quantitative ELISA Human HNE sandwich (serum, plasma, tissue homogenates), result in 3.5 h.

This ELISA ELK Biotechnology kit allows the quantitative in vitro determination of human HNE (4-Hydroxynonenal) in the following samples: serum, plasma and tissue homogenates.

The assay is based on the ELISA sandwich technique: the microtitration plate is pre-coatted with a specific antibody of HNE. Standards or samples are added, followed by a biotinylated and l-avidine detection antibody coupled with peroxidase (HRP). After addition of the TMB substrate and cessation of the sulfuric acid reaction, the optical density is measured at 450 nm ± 10 nm; the concentration is determined using the standard curve.

Research-only product (RUO), not intended for diagnosis.

Sensitivity

Sensitivity of 1.21 ng/mL.

Range of dosage

Range of 3.13 to 200 ng/mL (highest standard: 200 ng/mL).

Samples

Serum, plasma and tissue homogenates.

Rapidity

Result in 3.5 hours.

Specificity

Sandwich format, human HNE specific antibodies.

Reproducibility

Intra-test accuracy CV < 8%, inter-test CV < 10%.

Technical specifications

General
BrandELK Biotechnology
RangeStandard
Specifications
Format48 tests (1 plate of 48 wells)
SpeciesHuman
TargetHNE (4-Hydroxynonenal)
Type of dosageELISA sandwich
Performance
Sensitivity1.21 ng/mL
Range of dosage3.13 – 200 ng/mL
Standard (maximum concentration)200 ng/mL
Duration of dosing3.5 h
Readability wave length450 nm ± 10 nm
Specifications
SamplesSerum, plasma and tissue homogenates
Research areaSignal Transduction, Metabolic Pathways, Anti-Infectious Immunity, Hormonal Metabolism, Dermatology
Alternative names4-HNE; HNE; 4-hydroxy-2-nonenal; 4-Hydroxynonenal
Storage and shipping
ShippingWith ice loaves, without carboglace
Compliance
Useresearch use only (RUO)
Validation
Intra-test accuracyCV < 8 %
Inter-test accuracyCV < 10 %
Standard curve (example)200.00 ng/mL : DO 2.045; 100.00 ng/mL : DO 1.562; 50.00 ng/mL : DO 1.285; 25.00 ng/mL : DO 0.915; 12.50 ng/mL : DO 0.634; 6.25 ng/mL : DO 0.389; 3.13 ng/mL : DO 0.258; 0.00 ng/mL : DO 0.068
Recovery (doped samples)serum (n=5): 84-98% (average 91%); EDTA plasma (n=5): 79-97% (average 88%); heparin plasma (n=5): 80-95% (average 87%)
Linearity (dilutions)serum (n=5): 1:2 86-93%, 1:4 91-105%, 1:8 87-98%, 1:16 89-94%; EDTA plasma (n=5): 1:2 95-103%, 1:4 79-92%, 1:8 97-105%, 1:16 89-97%; heparin plasma (n=5): 1:2 85-94%, 1:4 97-106%, 1:8 82-95%, 1:16 93-105%
Conservation
Storage of kitKit not open: 2-8 °C for 6 months, or -20 °C for 1 year; avoid freeze-thaw cycles.
Safety data sheetDownloadable with a B-LABO account

Origin and customs

Manufacturer ref.ELK0114-48T
Country of originChina
HS customs code3822 19 00 00

Scope of delivery

  • Pre-coated microplate: 6 strips × 8 wells (conservation 4 °C or -20 °C)
  • Standard lyophilized: 1 vial (storage 4 °C or -20 °C)
  • Biotinylated detection antibody (100×): 60 μL (storage 4 °C or -20 °C)
  • Streptavidine-HRP (100×): 60 μL (storage 4 °C or -20 °C)
  • Standard dilution stamp/samples: 10 mL (storage 4 °C or -20 °C)
  • Biotinyl antibody diluent: 6 mL (storage 4 °C or -20 °C)
  • HRP diluent: 6 mL (storage 4 °C or -20 °C)
  • Wash pad (25×): 10 mL (storage 4°C or -20°C)
  • TMB substrate solution: 6 mL (storage 4 °C or -20 °C (in the shelter of light))
  • Stopping solution: 3 mL (storage 4 °C or -20 °C)
  • Adhesive film for plate: 1 piece (storage of room temperature)

Documentation

Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account.
Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration?
Contact us for a quote.