Human HNE(4-Hydroxynonenal) ELISA Kit, 5 x 96 tests. For research use only.
Format
5 × 96 tests (5 plates of 96 wells)
Species
Human
Target
HNE (4-Hydroxynonenal)
Type of dosage
ELISA sandwich
Sensitivity
1.21 ng/mL
Brand
ELK Biotechnology
Quantitative ELISA Human HNE sandwich (serum, plasma, tissue homogenates), result in 3.5 h.
This ELISA ELK Biotechnology kit allows the quantitative in vitro determination of human HNE (4-Hydroxynonenal) in the following samples: serum, plasma and tissue homogenates.
The assay is based on the ELISA sandwich technique: the microtitration plate is pre-coatted with a specific antibody of HNE. Standards or samples are added, followed by a biotinylated and l-avidine detection antibody coupled with peroxidase (HRP). After addition of the TMB substrate and cessation of the sulfuric acid reaction, the optical density is measured at 450 nm ± 10 nm; the concentration is determined using the standard curve.
Research-only product (RUO), not intended for diagnosis.
Sensitivity
Sensitivity of 1.21 ng/mL.
Range of dosage
Range of 3.13 to 200 ng/mL (highest standard: 200 ng/mL).
Samples
Serum, plasma and tissue homogenates.
Rapidity
Result in 3.5 hours.
Specificity
Sandwich format, human HNE specific antibodies.
Reproducibility
Intra-test accuracy CV < 8%, inter-test CV < 10%.
Technical specifications
General
Brand
ELK Biotechnology
Range
Standard
Specifications
Format
5 × 96 tests (5 plates of 96 wells)
Species
Human
Target
HNE (4-Hydroxynonenal)
Type of dosage
ELISA sandwich
Performance
Sensitivity
1.21 ng/mL
Range of dosage
3.13 – 200 ng/mL
Standard (maximum concentration)
200 ng/mL
Duration of dosing
3.5 h
Readability wave length
450 nm ± 10 nm
Specifications
Samples
Serum, plasma and tissue homogenates
Research area
Signal Transduction, Metabolic Pathways, Anti-Infectious Immunity, Hormonal Metabolism, Dermatology
Alternative names
4-HNE; HNE; 4-hydroxy-2-nonenal; 4-Hydroxynonenal
Storage and shipping
Shipping
With ice loaves, without carboglace
Compliance
Use
research use only (RUO)
Validation
Intra-test accuracy
CV < 8 %
Inter-test accuracy
CV < 10 %
Standard curve (example)
200.00 ng/mL : DO 2.045; 100.00 ng/mL : DO 1.562; 50.00 ng/mL : DO 1.285; 25.00 ng/mL : DO 0.915; 12.50 ng/mL : DO 0.634; 6.25 ng/mL : DO 0.389; 3.13 ng/mL : DO 0.258; 0.00 ng/mL : DO 0.068
Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account. Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration? Contact us for a quote.