Human NE(Noradrenaline) ELISA Kit – 48 tests

Ref.: BL-RE-988873Manufacturer ref.: ELK9243-48T 48 tests
€363.00 excl. VAT

Human NE(Noradrenaline) ELISA Kit, 48 tests. For research use only.

Format
48 tests (1 plate of 48 wells)
Species
Human
Target
NE (Noradrenaline)
Type of dosage
ELISA by competition
Sensitivity
24.1 pg/mL
Brand
ELK Biotechnology

ELISA quantitative assay by human NE competition (serum, plasma, cell lysates, cell culture supernatants), 2 h result.

This ELISA ELK Biotechnology kit allows the quantitative in vitro determination of human NE (Noradrenaline) in the following samples: serum, plasma, cell lysates, cell culture supernatants and other biological fluids.

The assay is based on ELISA by competition: the microtitration plate is pre-coatted with the target antigen. Standards or samples are added with a specific biotinylated antibody, then l-avidine coupled with peroxidase (HRP). After addition of the TMB substrate, the colour intensity measured at 450 nm ± 10 nm is inversely proportional to the concentration of NE.

Research-only product (RUO), not intended for diagnosis.

Sensitivity

Sensitivity of 24.1 pg/mL.

Range of dosage

The range of the assay is 78.13 to 5000 pg/mL (highest standard: 5000 pg/mL).

Samples

Serum, plasma, cell lysates, cell culture supernatants and other biological fluids.

Rapidity

Result in 2 hours.

Specificity

Format by competition, specific antibodies of human NE.

Reproducibility

Intra-test accuracy CV < 8%, inter-test CV < 10%.

Technical specifications

General
BrandELK Biotechnology
RangeStandard
Specifications
Format48 tests (1 plate of 48 wells)
SpeciesHuman
TargetNE (Noradrenaline)
Type of dosageELISA by competition
Performance
Sensitivity24.1 pg/mL
Range of dosage78.13 – 5000 pg/mL
Standard (maximum concentration)5000 pg/mL
Duration of dosing2 h
Readability wave length450 nm ± 10 nm
Specifications
SamplesSerum, plasma, cell lysates, cell culture supernatants and other biological fluids
Research areaSignal transduction, Anti-infectious immunity, Neurosciences, Hormonal metabolism
Alternative namesNA; NAd; Norepinephrine; Norepi
Storage and shipping
ShippingWith ice loaves, without carboglace
Compliance
Useresearch use only (RUO)
Validation
Intra-test accuracyCV < 8 %
Inter-test accuracyCV < 10 %
Standard curve (example)5000.00 pg/mL : DO 0.235; 0.332 pg/mL : DO 1250.00; 625.00 pg/mL : DO 0.833; 1.127 pg/mL : DO 156.25; 78.13 pg/mL : DO 1.877
Recovery (doped samples)serum (n=5): 87-99% (average 93 %); EDTA plasma (n=5): 87-99% (average 93 %); heparin plasma (n=5): 80-96% (average 88 %)
Linearity (dilutions)serum (n=5): 1:2 79-96 %, 1:4 89-101%, 1:8 88-97%, 1:16 97-105%; EDTA plasma (n=5): 1:2 81-93%, 1:4 89-102%, 1:8 87-95%, 1:16 85-96 %; heparin plasma (n=5): 1:2 92-102%, 1:4 81-92%, 1:8 86-93%, 1:16 91-103%
Conservation
Storage of kitKit not open: 2-8 °C for 6 months, or -20 °C for 1 year; avoid freeze-thaw cycles.
Safety data sheetDownloadable with a B-LABO account

Origin and customs

Manufacturer ref.ELK9243-48T
Country of originChina
HS customs code3822 19 00 00

Scope of delivery

  • Pre-coated microplate: 6 strips × 8 wells (conservation 4 °C or -20 °C)
  • Standard lyophilized: 1 vial (storage 4 °C or -20 °C)
  • Biotinylated -Conjugate (100×): 30 μL (storage 4 °C or -20 °C)
  • Streptavidine-HRP (100×): 60 μL (storage 4 °C or -20 °C)
  • Standard dilution stamp/samples: 10 mL (storage 4 °C or -20 °C)
  • Biotinylated -Diluent conjugate: 5 mL (storage 4 °C or -20 °C)
  • HRP diluent: 6 mL (storage 4 °C or -20 °C)
  • Wash pad (25×): 10 mL (storage 4°C or -20°C)
  • TMB substrate solution: 6 mL (storage 4 °C or -20 °C (in the shelter of light))
  • Stopping solution: 3 mL (storage 4 °C or -20 °C)
  • Adhesive film for plate: 1 piece (storage of room temperature)

Documentation

Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account.
Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration?