Human NE(Noradrenaline) ELISA Kit – 5 x 96 tests

Ref.: BL-RE-988875Manufacturer ref.: ELK9243-5x96T 5 × 96 tests
€2,181.00 excl. VAT

Human NE(Noradrenaline) ELISA Kit, 5 x 96 tests. For research use only.

Format
5 × 96 tests (5 plates of 96 wells)
Species
Human
Target
NE (Noradrenaline)
Type of dosage
ELISA by competition
Sensitivity
24.1 pg/mL
Brand
ELK Biotechnology

ELISA quantitative assay by human NE competition (serum, plasma, cell lysates, cell culture supernatants), 2 h result.

This ELISA ELK Biotechnology kit allows the quantitative in vitro determination of human NE (Noradrenaline) in the following samples: serum, plasma, cell lysates, cell culture supernatants and other biological fluids.

The assay is based on ELISA by competition: the microtitration plate is pre-coatted with the target antigen. Standards or samples are added with a specific biotinylated antibody, then l-avidine coupled with peroxidase (HRP). After addition of the TMB substrate, the colour intensity measured at 450 nm ± 10 nm is inversely proportional to the concentration of NE.

Research-only product (RUO), not intended for diagnosis.

Sensitivity

Sensitivity of 24.1 pg/mL.

Range of dosage

The range of the assay is 78.13 to 5000 pg/mL (highest standard: 5000 pg/mL).

Samples

Serum, plasma, cell lysates, cell culture supernatants and other biological fluids.

Rapidity

Result in 2 hours.

Specificity

Format by competition, specific antibodies of human NE.

Reproducibility

Intra-test accuracy CV < 8%, inter-test CV < 10%.

Technical specifications

General
BrandELK Biotechnology
RangeStandard
Specifications
Format5 × 96 tests (5 plates of 96 wells)
SpeciesHuman
TargetNE (Noradrenaline)
Type of dosageELISA by competition
Performance
Sensitivity24.1 pg/mL
Range of dosage78.13 – 5000 pg/mL
Standard (maximum concentration)5000 pg/mL
Duration of dosing2 h
Readability wave length450 nm ± 10 nm
Specifications
SamplesSerum, plasma, cell lysates, cell culture supernatants and other biological fluids
Research areaSignal transduction, Anti-infectious immunity, Neurosciences, Hormonal metabolism
Alternative namesNA; NAd; Norepinephrine; Norepi
Storage and shipping
ShippingWith ice loaves, without carboglace
Compliance
Useresearch use only (RUO)
Validation
Intra-test accuracyCV < 8 %
Inter-test accuracyCV < 10 %
Standard curve (example)5000.00 pg/mL : DO 0.235; 0.332 pg/mL : DO 1250.00; 625.00 pg/mL : DO 0.833; 1.127 pg/mL : DO 156.25; 78.13 pg/mL : DO 1.877
Recovery (doped samples)serum (n=5): 87-99% (average 93 %); EDTA plasma (n=5): 87-99% (average 93 %); heparin plasma (n=5): 80-96% (average 88 %)
Linearity (dilutions)serum (n=5): 1:2 79-96 %, 1:4 89-101%, 1:8 88-97%, 1:16 97-105%; EDTA plasma (n=5): 1:2 81-93%, 1:4 89-102%, 1:8 87-95%, 1:16 85-96 %; heparin plasma (n=5): 1:2 92-102%, 1:4 81-92%, 1:8 86-93%, 1:16 91-103%
Conservation
Storage of kitKit not open: 2-8 °C for 6 months, or -20 °C for 1 year; avoid freeze-thaw cycles.
Safety data sheetDownloadable with a B-LABO account

Origin and customs

Manufacturer ref.ELK9243-5x96T
Country of originChina
HS customs code3822 19 00 00

Scope of delivery

  • 5 kits of 96 tests, each containing:
  • Pre-coated microplate: 12 strips × 8 wells (conservation 4 °C or -20 °C)
  • Standard lyophilized: 2 vials (storage 4 °C or -20 °C)
  • Biotinylated -Conjugate (100×): 60 μL (storage 4 °C or -20 °C)
  • Streptavidine-HRP (100×): 120 μL (storage 4 °C or -20 °C)
  • Standard dilution stamp/samples: 20 mL (storage 4 °C or -20 °C)
  • Biotinylated -Diluent conjugate: 10 mL (storage 4 °C or -20 °C)
  • HRP diluent: 12 mL (storage 4 °C or -20 °C)
  • Wash pad (25×): 20 mL (storage 4°C or -20°C)
  • TMB substrate solution: 10 mL (storage 4°C or -20°C (in the shelter of light))
  • Stop solution: 6 mL (storage 4 °C or -20 °C)
  • Adhesive film for plate: 2 pieces (storage of room temperature)

Documentation

Manufacturer SDS (ELK Biotechnology). Free download after signing in or creating an account.
Customers who have ordered: the SDS is attached automatically to the order confirmation.
A question or a specific configuration?