| Marque | Thermo Scientific |
| Réf. B-LABO | BL-EQ-173378 |
| Réf. fabricant | 30245790 |
| Comprend | Meter with stand (PSTAR2130), optical DO/ATC electrode with calibration sleeve, guard and optical cap (087010MD) |
|---|
| Correction de la pression barométrique | Yes, automatic with built-in barometer or manual |
|---|
| Sorties | USB flash drive, computer or printer (STARA-106) |
|---|
| À utiliser avec (application) | Wide variety of dissolved oxygen samples using optical DO electrode |
|---|
| Measurement Modes | Dissolved Oxygen (mg/L with Temperature and Barometric Pressure), Dissolved Oxygen (ppm with Temperature and Barometric Pressure), Dissolved Oxygen (% Saturation with Temperature and Barometric Pressure) |
|---|
| Types de capteur | RDO Optical Dissolved Oxygen Sensor |
|---|
| Gamme (OD par mesure polarographique) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
|---|
| Résolution (OD par mesure polarographique) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
|---|
| Précision (OD par mesure polarographique) | ±2% saturation; ±0.02 mg/L or ppm |
|---|
| Gamme de pression | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
|---|
| Modes d’étalonnage | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
|---|
| Plage (métrique) de températures | -30.0°C to +130.0°C |
|---|
| Résolution (température) | 0.1°C, 0.1°F |
|---|
| Précision (température) | ±0.3°C, ±0.5°F |
|---|
| Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
|---|
| Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
|---|
| Type d’affichage | 7-in. High-resolution Color Graphic LCD |
|---|
| Option de rétro-éclairage | Yes |
|---|
| Mémoire | Non-volatile |
|---|
| Points de données | 10,000 with Date and Time Stamp |
|---|
| Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
|---|
| Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
|---|
| Entrées | 9-pin MiniDIN for dissolved oxygen with ATC |
|---|
| Certifications/Conformité | CE, TUV 3-1, FCC Class A |
|---|
| Indice IP | IP54 |
|---|
| Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
|---|
| Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
|---|
| Poids (métrique) | 1.00 kg |
|---|
| Poids (impériale) | 2.20 lbs. |
|---|
| Gamme d’humidité relative | 5 to 85%, non-condensing |
|---|
| Garantie | 2 year meter warranty |
|---|
| Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
|---|
| Clavier | Capacitive touchscreen user interface |
|---|
| Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
|---|
| Précision (RDO) | ±2% saturation; ±0.02 mg/L or ppm |
|---|
| Gamme (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
|---|
| Méthodes | 10 |
|---|
| Modèle | DO213 |
|---|
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
|---|
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
|---|
| Plage de saturation en pourcentage (RDO) | 0.0 to 600.0% saturation |
|---|
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
|---|
| Résolution du coefficient de saturation (RDO) | 0.1, 1% saturation |
|---|
| Type de sonde | Polarographic or optical DO electrode |
|---|
| Gamme (OD) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
|---|
| Résolution (OD) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
|---|
| Canaux | 1 |
|---|
| Résolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
|---|
| Facteur de salinité | 0.0 to 50.0 ppt |
|---|
| Type | DO Bench Meter Optical Kit |
|---|
| Précision (baromètre) | ±6.0 mmHg; ±0.008 bar |
|---|
| Précision (DO) | ±2% saturation; ±0.02 mg/L or ppm |