The Human Troponin I (TNNI3) ELISA quantitates Hu TNNI3 in human serum, plasma, or cell culture medium. The assay will exclusively recognize both natural and recombinant Hu TNNI3. Principle of the method The Human TNNI3 solid-phase sandwich ELISA (enzyme-linked immunosorbent assay) is designed to measure the amount of the target bound between a matched antibody pair. A target-specific antibody has been pre-coated in the wells of the supplied microplate. Samples, standards, or controls are then added into these wells and bind to the immobilized (capture) antibody. The sandwich is formed by the addition of the second (detector) antibody, a substrate solution is added that reacts with the enzyme-antibody-target complex to produce measurable signal. The intensity of this signal is directly proportional to the concentration of target present in the original specimen. Rigorous validation Each manufactured lot of this ELISA kit is quality tested for criteria such as sensitivity, specificity, precision, and lot-to-lot consistency. See manual for more information on validation.
La troponine cardiaque I (troponine I, TnI, troponine I spécifique au cœur) est une protéine inhibitrice intégrale dans le muscle cardiaque qui existe dans le cadre d’un complexe avec la troponine C (TnC) et la troponine T (TnT). La sous-unité TnT de la troponine se lie à la forme tropomyosine-t, un complexe troponine-tropomyosine, ancré en place par la liaison du TnI à l’actine, dans les filaments fins des cellules musculaires. Le changement structurel résultant de la liaison du calcium à des sites spécifiques de la sous-unité TnC régulatrice libère la région inhibitrice de TnI de l’actine, ce qui permet d’isoler la myosine de la protéine moteur moléculaire, ce qui permet la contraction musculaire et donc le mouvement. Les mesures des taux de TnI et de TnT dans le sang sont des indicateurs diagnostiques importants des lésions musculaires cardiaques et peuvent être utilisées pour différencier l’angine de poitrine et l’infarctus du myocarde chez les patients souffrant de douleurs thoraciques. Il a également été démontré que la troponine cardiaque I inhibe l’angiogenèse in vivo et in vitro. Les mutations du gène Troponine cardiaque I provoquent une cardiomyopathie hypertrophique familiale de type 7 (CMH7) et une cardiomyopathie restrictive familiale (RCM).
Caractéristiques techniques
| Marque | Invitrogen |
| Réf. B-LABO | BL-RE-105984 |
| Réf. fabricant | 15455163 |
| Numéro d’adhésion | P19429 |
|---|
| Plage de dosage | 125-8000 pg/ml |
|---|
| Sensibilité du dosage | 100 pg/ml |
|---|
| Plage d’étalonnage | 100 pg/ml à 8000 pg/ml |
|---|
| Doser | ELISA sandwich en phase solide |
|---|
| Conjugué | Biotine |
|---|
| Type de produit | Kit ELISA |
|---|
| Famille de protéines | Autres protéines |
|---|
| Type d’échantillon | Sérum, Surnageant, Surnageant |
|---|
| Spécificité | Cet anticorps de la paire ELISA détecte la cTnI humaine. Autres espèces non encore déterminées. |
|---|
| Suffisant pour | 96 dosages |
|---|
| Espèces cibles | Humaine |
|---|
| À utiliser avec (application) | ELISA, dosage des protéines, biologie des protéines, cancérologie, immunologie, neuroscience, neurobiologie, détection des protéines, analyses protéiques |
|---|
| À utiliser avec (équipement) | Lecteur de microplaques colorimétriques |
|---|
| Identification génétique (Entrez) | 7137 |
|---|
| Symbole de gène(s) | CMD1FF,CMD2A,CMH7,RCM1,TNNC1,cTnI |
|---|
| Coefficient de variation inter-dosage | < 12 % |
|---|
| Coefficient de variation intra-dosage | < 10 % |
|---|
| Contenus des kits | Plaque à 96 puits pré-enduite, Étalon, Concentrat de diluant de dosage, Anticorps de détection biotinylé, Tampon de lavage, Chromogène, Solution d’arrêt, Couvercles de plaques adhésives, Couvercles de plaques adhésives |
|---|
| Marqueur ou colorant | HRP |
|---|
| Quantité | 96 tests |
|---|
| État réglementaire | RUO |
|---|
| Disciplines de recherche | Recherches cardiovasculaires |
|---|
| Volume d’échantillon | Plasma, 50 μl ; sérum, 50 μl ; surnageant, 100 μl |
|---|
| Conditions de stockage | 2°C à 8°C |
|---|
| Synonyme | CMD1FF, CMD2A, CMH7, RCM1, TNNC1, cTnI |
|---|
| Cible | Humaine |
|---|
| Heure du test | 1 h 20 min |
|---|
| Durée totale du dosage | 4 h 45 min |