"/> Invitrogen™ Kit ELISA Androgen Receptor humain | B-LABO France

Invitrogen™ Kit ELISA Androgen Receptor humain

Réf. : BL-RE-106140Réf. fabricant : 18047414 96 Tests
618,00 € HT

For the quantitative detection of Human Androgen Receptor

Numéro d’adhésion
P10275
Plage de dosage
0.31 to 20 ng/mL
Sensibilité du dosage
0.19 ng/mL
Conjugué
HRP
Type de produit
ELISA
Marque
Invitrogen

The androgen receptor (AR) is a member of the steroid-hormone receptor superfamily of nuclear receptors. The receptor is more than 90 kDa and has three major functional domains: the N-terminal domain, DNA-binding domain, and the androgen-binding domain. The androgen receptor is a ligand-activated transcription factor that binds active testosterone (T) and dihydrotestosterone (DHT). Upon binding the hormone ligand, the receptor dissociates from accessory proteins, translocates into the nucleus, dimerizes, and then stimulates transcription of androgen responsive genes. The AR signaling pathway plays a key role in development and function of male reproductive organs, including the prostate and epididymis. AR also plays a role in nonreproductive organs, such as muscle, hair follicles, and brain. Androgen Receptor is a phosphoprotein, and also regulates mitogen-activated protein kinase (MAP kinase). The inhibition of the MEK1/2 pathway correlates directly with a change in phosphorylation state of the androgen receptor. Abnormalities in the AR signaling pathway have been linked to a number of diseases, including prostate cancer, Kennedy's disease, and male infertility. Mutations in this gene are associated with complete androgen insensitivity (CAIS).

Caractéristiques techniques

MarqueInvitrogen
Réf. B-LABOBL-RE-106140
Réf. fabricant18047414
Numéro d’adhésionP10275
Plage de dosage0.31 to 20 ng/mL
Sensibilité du dosage0.19 ng/mL
ConjuguéHRP
Type de produitELISA
Type d’échantillonSerum
À utiliser avec (équipement)Colorimetric Microplate Reader
Identification génétique (Entrez)367
Symbole de gène(s)AR
Coefficient de variation inter-dosage<10%
Coefficient de variation intra-dosage<10%
Contenus des kitsPre-coated 96 well plate, Standard, Biotinylated Detection Antibody, HRP Conjugate, Standard & Sample Diluent, Biotinylated Detection Antibody Diluent, HRP Conjugate Diluent, Wash Buffer, TMB Substrate, Stop Solution, Plate Sealer
Marqueur ou colorantHRP
Quantité96 Tests
État réglementaireRUO
Volume d’échantillon100 µL
Conditions de stockageRefer to product documentation for component specific storage temperature.
CibleHuman
Heure du test1 hr 20 min
Durée totale du dosage3 hr 30 min
Une question, une configuration particulière ?
Contactez-nous pour un devis.