S100B is a member of the S100 family of proteins containing 2 EF-hand calcium-binding motifs. S100 proteins are localized in the cytoplasm and/or nucleus of a wide range of cells and are involved in the regulation of a number of cellular processes…
S100B is a member of the S100 family of proteins containing 2 EF-hand calcium-binding motifs. S100 proteins are localized in the cytoplasm and/or nucleus of a wide range of cells and are involved in the regulation of a number of cellular processes such as cell cycle progression and differentiation. S100B may function in neurite extension, proliferation of melanoma cells, stimulation of Ca2+ fluxes, inhibition of PKC-mediated phosphorylation, astrocytosis and axonal proliferation, and inhibition of microtubule assembly. Chromosomal rearrangements and altered expression of this gene have been implicated in several diseases, including Alzheimer's disease, Down's syndrome, epilepsy, amyotrophic lateral sclerosis, melanoma, and type I diabetes.
Sensibilité
Sensibilité du dosage : 46,88 pg/mL.
Plage de mesure
Plage de dosage : 78,13 à 5000 pg/mL.
Durée du dosage
Durée totale du dosage : 3 h 30 min.
Échantillons
Type d’échantillon : Plasma (volume 100 µL).
Caractéristiques techniques
| Général |
| Marque | Invitrogen |
| Réf. fournisseur (Fisher Scientific) | 18037464 |
| Caractéristiques |
| Numéro d’adhésion | P50114 |
| Plage de dosage | 78.13 to 5000 pg/mL |
| Sensibilité du dosage | 46.88 pg/mL |
| Conjugué | HRP |
| Type de produit | ELISA |
| Type d’échantillon | Plasma |
| À utiliser avec (équipement) | Colorimetric Microplate Reader |
| Identification génétique (Entrez) | 20203 |
| Symbole de gène(s) | S100B |
| Coefficient de variation inter-dosage | <10% |
| Coefficient de variation intra-dosage | <10% |
| Contenus des kits | Pre-coated 96 well plate, Standard, Biotinylated Detection Antibody, HRP Conjugate, Standard & Sample Diluent, Biotinylated Detection Antibody Diluent, HRP Conjugate Diluent, Wash Buffer, TMB Substrate, Stop Solution, Plate Sealer |
| Marqueur ou colorant | HRP |
| Quantité | 96 Tests |
| État réglementaire | RUO |
| Cible | Mouse |
| Heure du test | 1 hr 20 min |
| Caractéristiques physiques |
| Volume d’échantillon | 100 µL |
| Stockage et expédition |
| Conditions de stockage | Refer to product documentation for component specific storage temperature. |
| Durée totale du dosage | 3 hr 30 min |
Origine et douane
| Réf. fabricant | EEL109 |
|---|
| Pays d’origine | Chine |
|---|
| Code douanier (SH) | 3822 11 00 00 |
|---|
Une question, une configuration particulière ?