"/> Cytiva HiTrap™ MabSelect™ Prepacked Columns | B-LABO France

Cytiva HiTrap™ MabSelect™ Prepacked Columns

Réf. : BL-RE-126892Réf. fabricant : 10359534 5 Pk.
1 041,00 € HT

Use these columns in small-scale MAb purification in a continuous bioprocess. Cytiva Life Sciences™ HiTrap™ MabSelect™ Prepacked Columns for fast purification of monoclonal antibodies (Mabs) from large sample volumes

Type de produit
Pre-packed Columns
Capacité de liaison
∼30 mg/mL Human lgG at 2.4 min. residence time
Diamètre (métrique) de la colonne intérieure
0.7 cm
Diamètre (impériale) de la colonne intérieure
0.27 in.
Débit
<4 mL/min.
Marque
Cytiva

Prepacked HiTrap columns for process development, screening of purification conditions, and small-scale purification of Mabs. MabSelect media are suited for the high flowrates and pressures required when scaling up.

Points forts

MabSelect

  • Allows at least five times higher flowrates than conventional cross-linked agarose of similar porosity
  • Recombinant Protein A ligand promotes specificity of binding to Fc region of IgG; permits one-step purification

MabSelect Xtra™

  • Same recombinant protein A ligand as MabSelect, but with a smaller particle size and greater porosity, for increased dynamic binding capacity
  • Allows binding from samples with high expression levels of the monoclonal antibody
  • Lowers overall production cost due to the possibility of processing concentrated feedstocks in fewer batches

MabSelect SuRe™ (Superior Resistance)

  • Akali-tolerant protein A-derived ligand allows the use of up to 0.5M NaOH for cleaning-in-place (CIP)
  • Permits significant cost savings and extension of cycles in regular production

Caractéristiques principales

  • Oriented coupling of recombinant Protein A ligand to the agarose matrix via an engineered C-terminal cysteine increases IgG binding capacity over other protein A media
  • High capacity, low ligand leakage, and high-flow base matrix allow purification of Mabs at process scale
  • Fewer regulatory concerns due to the total absence of mammalian culture in the ligand production and purification
  • Designed for use with a syringe, a peristaltic pump, or a chromatography system

Caractéristiques techniques

MarqueCytiva
Réf. B-LABOBL-RE-126892
Réf. fabricant10359534
Type de produitPre-packed Columns
Capacité de liaison∼30 mg/mL Human lgG at 2.4 min. residence time
Diamètre (métrique) de la colonne intérieure0.7 cm
Diamètre (impériale) de la colonne intérieure0.27 in.
Débit<4 mL/min.
Volume (métrique) du lit1 mL
À utiliser avec (application)For fast purification of monoclonal antibodies from large sample volumes, Protein Purification
Volume d’échantillon1 mL
Tampon de stockage20% Ethanol
Contenu et stockage4°C to 30°C
Quantité5 Pk.
Une question, une configuration particulière ?