Invitrogen™ Kit ELISA MCP-2/CCL8 humain
Sandwich ELISA Kit
- Numéro d’adhésion
- P80075
- Plage de dosage
- 0,82-200 pg/ml
- Sensibilité du dosage
- 1,5 pg/ml
- Plage d’étalonnage
- 1,5 pg/ml à 200 pg/ml
- Doser
- ELISA sandwich en phase solide
- Marque
- Invitrogen
"/>
Sandwich ELISA Kit
The Human Monocyte Chemoattractant Protein-2/CCL8 (Hu MCP-2 ELISA quantitates Hu MCP-2 in human serum, plasma, or cell culture medium. The assay will exclusively recognize both natural and recombinant Hu MCP-2. Principle of the method The Human MCP-2 solid-phase sandwich ELISA (enzyme-linked immunosorbent assay) is designed to measure the amount of the target bound between a matched antibody pair. A target-specific antibody has been pre-coated in the wells of the supplied microplate. Samples, standards, or controls are then added into these wells and bind to the immobilized (capture) antibody. The sandwich is formed by the addition of the second (detector) antibody, a substrate solution is added that reacts with the enzyme-antibody-target complex to produce measurable signal. The intensity of this signal is directly proportional to the concentration of target present in the original specimen. Rigorous validation Each manufactured lot of this ELISA kit is quality tested for criteria such as sensitivity, specificity, precision, and lot-to-lot consistency. See manual for more information on validation.
Ce gène est l’un des différents gènes de cytokines regroupés sur le bras q du chromosome 17. Les cytokines sont une famille de protéines sécrétées impliquées dans les processus immunorégulateurs et inflammatoires. La protéine codée par ce gène est structurellement liée à la sous-famille CXC des cytokines. Les membres de cette sous-famille sont caractérisés par deux cystéines séparées par un seul acide aminé. Cette cytokine affiche lʼactivité chimiotactique des monocytes, des lymphocytes, des basophiles et des éosinophiles. En recrutant des leucocytes aux sites dʼinflammation, cette cytokine peut contribuer à lʼinfiltration des leucocytes associés aux tumeurs et à lʼétat antiviral contre lʼinfection par le VIH.
| Marque | Invitrogen |
|---|---|
| Réf. B-LABO | BL-RE-143645 |
| Réf. fabricant | 15494933 |
| Numéro d’adhésion | P80075 |
| Plage de dosage | 0,82-200 pg/ml |
| Sensibilité du dosage | 1,5 pg/ml |
| Plage d’étalonnage | 1,5 pg/ml à 200 pg/ml |
| Doser | ELISA sandwich en phase solide |
| Conjugué | Biotine |
| Type de produit | Kit ELISA |
| Famille de protéines | Chimiokine & récepteurs |
| Type d’échantillon | Sérum, Surnageant, Surnageant |
| Spécificité | Ce kit ELISA ne montre aucune réactivité croisée avec les cytokines testées : angiogénine humaine, BDNF, BLC, ENA-78, FGF-4, IL-1 alpha, IL-1 bêta, IL-2, IL-3, IL-4, IL-5, IL-7, IL-8, IL-9, IL-10, IL-11, IL-12 p70, IL-12 p40, IL-13, IL-15, IL-309, IP-10, G-CSF, GM-CSF, IFN-gamma, leptine, MCP-1, MCP-3, MDC, MIP-1 alpha, MIP-1 bêta, MIP-1 delta, PARC, PDGF, RANTES, SCF, TARC, TGF-bêta, TIMP-1, TIMP-2, TNF-alpha, TNF-bêta, TPO, VEGF. |
| Suffisant pour | 96 dosages |
| Espèces cibles | Humaine |
| À utiliser avec (application) | ELISA, dosage des protéines, biologie des protéines, cancérologie, immunologie, neuroscience, neurobiologie, détection des protéines, analyses protéiques |
| À utiliser avec (équipement) | Lecteur de microplaques colorimétriques |
| Identification génétique (Entrez) | 6355 |
| Symbole de gène(s) | HC14,MCP-2,MCP2,SCYA10,SCYA8 |
| Coefficient de variation inter-dosage | < 12 % |
| Coefficient de variation intra-dosage | < 10 % |
| Contenus des kits | Plaque à 96 puits pré-enduite, Étalon, Concentrat de diluant de dosage, Anticorps de détection biotinylé, Tampon de lavage, Chromogène, Solution d’arrêt, Couvercles de plaques adhésives, Couvercles de plaques adhésives |
| Marqueur ou colorant | HRP |
| Quantité | 96 tests |
| État réglementaire | RUO |
| Disciplines de recherche | Inflammation |
| Volume d’échantillon | Plasma, 50 μl ; sérum, 50 μl ; surnageant, 100 μl |
| Conditions de stockage | 2°C à 8°C |
| Synonyme | HC14, MCP-2, MCP2, SCYA10, SCYA8 |
| Cible | Humaine |
| Heure du test | 1 h 20 min |
| Durée totale du dosage | 4 h 45 min |