The Human GFAP Simplex ProcartaPlex Kit measures GFAP protein and is designed to be combinable with other Simplex kits so that you can create your own multiplex panel that utilizes Luminex xMAP technology for protein detection/quantitation. When…
The Human GFAP Simplex ProcartaPlex Kit measures GFAP protein and is designed to be combinable with other Simplex kits so that you can create your own multiplex panel that utilizes Luminex xMAP technology for protein detection/quantitation. When combining multiple Simplex kits (i.e., when you are not using a pre-configured Multiplex Panel), only one buffer kit (sold separately) is needed for each assay plate regardless of plex size.
About ProcartaPlex assays for the Luminex platform
ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate all protein targets simultaneously using a Luminex instrument. ProcartaPlex multiplex assays require as little as 25 μL of plasma or serum, or 50 μL of cell culture supernatant, and just four hours to obtain analyzed results.
ProcartaPlex assays utilize Luminex xMAP (multianalyte profiling) technology for the simultaneous detection and quantitation of up to 80 protein targets in a single 25–50 μL sample—from plasma, serum, cell culture supernatants, and other bodily fluids.
The Luminex beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create spectrally unique signatures that can be identified by the Luminex xMAP detection systems (e.g., Luminex 200, FLEXMAP 3D, and MAGPIX). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a multiplexed assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.
The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.
ProcartaPlex multiplex panels are available in multiple formats across six species (human, mouse, rat, nonhuman primate, porcine, and canine).
Reproducible, reliable results—validated as a…
Reproducible, reliable results—validated as a panel to the highest industry standard, including protein target combinability and cross-reactivity testing
More results per sample—measure multiple protein…
More results per sample—measure multiple protein targets simultaneously in a single 25–50 μL sample
Well-established Luminex technology highly…
Well-established Luminex technology highly referenced multiplexing platform for protein detection and quantitation
Caractéristiques techniques
| Général |
| Marque | Invitrogen |
| Réf. fournisseur (Fisher Scientific) | 30245124 |
| Caractéristiques |
| Type de produit | Simplex Kit |
| Quantité | 96 Tests |
| Espèces | Human |
| Combinability | Combinable |
| Type de microbilles | Magnetic |
| Zone des microbilles | GFAP [22] |
| Sensibilité du dosage | As determined for Lot 1: 2.26 pg/mL |
| Plage de dosage | As determined for Lot 1: 14-57900 pg/mL |
| À utiliser avec (équipement) | Luminex™ Instruments |
| Alias de gène | ALXDRD |
| Identification génétique (Entrez) | 2670 |
| Symbole de gène(s) | GFAP |
| Compatibilité à haut débit | Yes |
| Coefficient de variation inter-dosage | <15% |
| Coefficient de variation intra-dosage | <15% |
| Gamme de produits | ProcartaPlex |
| Type d’échantillon | Serum, Plasma, Cell Culture Supernatants |
| ID UniProt | P14136 |
| Synonyme | Glial fibrillary acidic protein |
| Research Area | Neurobiology, Immunology, Cardiovascular |
| Caractéristiques physiques |
| Volume d’échantillon | Serum, Plasma: 25 μL, CCS: 50 μL |
| Stockage et expédition |
| Contenu et stockage | <ul><li>2 vials Human Reference Plasma Standard</li><li>1 vial Capture Bead Mix (1X)</li><li>1 vial Biotinylated Detection Antibody Mix (50X)</li><li>1 bottle Detection Antibody Diluent (1X)</li><li>1 bottle Reading Buffer (1X)</li><li>1 bottle Streptavidin-PE (1X)</li><li>1 bottle Universal Assay B |
| Conditions d’expédition | Wet Ice |
Origine et douane
| Réf. fabricant | EPX01A-12336-901 |
|---|
| Pays d’origine | Autriche |
|---|
| Code douanier (SH) | 3822 19 00 00 |
|---|
Une question, une configuration particulière ?