The Serum Creatinine Colorimetric Detection Kit is designed to detect and quantify the level of creatinine in serum and plasma samples. The assay was validated for human, mouse, rabbit, rat, and sheep serum and EDTA and heparin plasma samples.
The Serum Creatinine Colorimetric Detection Kit is designed to detect and quantify the level of creatinine in serum and plasma samples. The assay was validated for human, mouse, rabbit, rat, and sheep serum and EDTA and heparin plasma samples.
This complete, ready-to-use kit includes clear two 96-well plate(s), Creatinine standard, assay diluent, and other components to perform the assay. A 96-well microplate reader capable of reading optical density at 490 nm is required for use of this kit.
Performance characteristics
• Assay type: colorimetric detection kit
• Sample types: serum and plasma (EDTA and heparin)
• Sensitivity: 0.081 μg/dL
• Standard curve range: 0.5–4 mg/dL
• Reactivity: species independent
Creatinine (2-amino-1-methyl-5H-imidazol-4-one) is a metabolite of phosphocreatine (p-creatine), a molecule used as a store for high-energy phosphate that can be utilized by tissues for the production of ATP. Creatine either comes from the diet or synthesized from the amino acids arginine, glycine, and methionine. This occurs in the kidneys and liver, although other organ systems may be involved and species-specific differences may exist. Creatine and p-creatine are converted non-enzymatically to the metabolite creatinine, which diffuses into the blood and is excreted by the kidneys. In vivo, this conversion appears to be irreversible and in vitro it is favored by higher temperatures and lower pH. Creatinine forms spontaneously from p-creatine. Under normal conditions, its formation occurs at a rate that is relatively constant and as intra-individual variation is
The Serum Creatinine Kit is designed to quantitatively measure creatinine present in serum samples. Please read the complete kit insert before performing this assay. A creatinine standard, calibrated to a NIST creatinine standard, is provided to generate a standard curve for the assay and all samples should be read off the standard curve. Standards or samples are pipetted into a clear microtiter plate. An assay diluent is added to all standards, controls, and samples. The color generating reaction is initiated with the Creatinine Reagent, which is pipetted into each well.
The assay utilizes a kinetic absorbance method to overcome interference by colored compounds in serum. The absorbance of the colored product is read after 1 minute in a microtiter plate reader capable of measuring 490 nm wavelength. At 30 minutes the optical density is read again. The concentration of creatinine is calculated using the delta of the optical density readings at 30 and 1 minute compared to the curve generated from the standards.
Espèces
Espèces : Universal.
Échantillons
Type d’échantillon : Plasma (EDTA, Heparin), Serum.
Compatibilité
Conçu pour une utilisation avec : Microplate Reader.
Conditionnement
Conditionnement : 192 Tests.
Caractéristiques techniques
| Général |
| Marque | Invitrogen |
| Réf. fournisseur (Fisher Scientific) | 18001653 |
| Caractéristiques |
| Format du kit d’immunoessai | Colorimetric Detection Kit |
| Type de produit | Serum Creatinine Colorimetric Detection Kit |
| Type d’échantillon | Plasma (EDTA, Heparin), Serum |
| Espèces cibles | Universal |
| À utiliser avec (équipement) | Microplate Reader |
| Quantité | 192 Tests |
| Kit cible nommé | Serum Creatinine |
| Stockage et expédition |
| Contenu et stockage | 96-well plate(s), standard, other assay specific reagents, buffers, and lot-specific technical data sheet. |
| Conditions d’expédition | Approved for shipment on Wet or Dry Ice |
Origine et douane
| Réf. fabricant | EIASCR |
|---|
| Pays d’origine | États-Unis |
|---|
| Code douanier (SH) | 3822 11 00 00 |
|---|