Invitrogen™ Kit ELISA Apolipoprotein A1 de souris

Réf. : BL-RE-171994Réf. fabricant : EEL116 96 Tests
694,00 € HT

Apolipoprotein A-1 (apo A-1) in human plasma is a major protein component of high density lipoprotein (HDL). The molecular mass is 24 kDa. Apo A-1 is a cofactor for enzymes involved in the normal turnover of cholesterol and is produced in the liver.…

Numéro d’adhésion
Q00623
Plage de dosage
0.63 to 40 ng/mL
Sensibilité du dosage
0.38 ng/mL
Conjugué
HRP
Type de produit
ELISA
Marque
Invitrogen

Apolipoprotein A-1 (apo A-1) in human plasma is a major protein component of high density lipoprotein (HDL). The molecular mass is 24 kDa. Apo A-1 is a cofactor for enzymes involved in the normal turnover of cholesterol and is produced in the liver.…

Apolipoprotein A-1 (apo A-1) in human plasma is a major protein component of high density lipoprotein (HDL). The molecular mass is 24 kDa. Apo A-1 is a cofactor for enzymes involved in the normal turnover of cholesterol and is produced in the liver. Plasma concentration is 270-380 mg/100 mL.

Sensibilité

Sensibilité du dosage : 0,38 ng/mL.

Plage de mesure

Plage de dosage : 0,63 à 40 ng/mL.

Durée du dosage

Durée totale du dosage : 3 h 30 min.

Échantillons

Type d’échantillon : Plasma (volume 100 µL).

Conjugué

Conjugué : HRP.

Caractéristiques techniques

Général
MarqueInvitrogen
Réf. fournisseur (Fisher Scientific)17986862
Caractéristiques
Numéro d’adhésionQ00623
Plage de dosage0.63 to 40 ng/mL
Sensibilité du dosage0.38 ng/mL
ConjuguéHRP
Type de produitELISA
Type d’échantillonPlasma
À utiliser avec (équipement)Colorimetric Microplate Reader
Identification génétique (Entrez)11806
Symbole de gène(s)APOA1
Coefficient de variation inter-dosage<10%
Coefficient de variation intra-dosage<10%
Contenus des kitsPre-coated 96 well plate, Standard, Biotinylated Detection Antibody, HRP Conjugate, Standard & Sample Diluent, Biotinylated Detection Antibody Diluent, HRP Conjugate Diluent, Wash Buffer, TMB Substrate, Stop Solution, Plate Sealer
Marqueur ou colorantHRP
Quantité96 Tests
État réglementaireRUO
CibleMouse
Heure du test1 hr 20 min
Caractéristiques physiques
Volume d’échantillon100 µL
Stockage et expédition
Conditions de stockageRefer to product documentation for component specific storage temperature.
Durée totale du dosage3 hr 30 min

Origine et douane

Réf. fabricantEEL116
Pays d’origineÉtats-Unis
Code douanier (SH)3002 15 00 00
Une question, une configuration particulière ?
Contactez-nous pour un devis.