Applied Biosystems™ MagMAX™ Viral/Pathogen Nucleic Acid Isolation Kit, for HIV-1 dried blood spots (DBS)

Réf. : BL-RE-174895Réf. fabricant : A53770 100 reactions
558,00 € HT

Duration: Test takes less than 60 minutes: ∼30 min DBS lysis, ∼30 min viral RNA extraction

Type de microbilles
Magnetic
Contenu et stockage
• 60 mL Dried Blood Spots Lysis Solution
• 55 mL Binding Solution
• 100 mL Wash Buffer
• 10 mL Elution Solution
• 1 mL Proteinase K
• 2 mL Total Nucleic Acid Binding Beads

Méthode de détection
HIV-1 viral RNA compatible with downstream applications such as RT-PCR and Sanger sequencing
Type d’échantillon
Whole Blood, Plasma
À utiliser avec (équipement)
KingFisher Duo Prime, KingFisher Flex, Magnetic Stand
Marque
Applied Biosystems

Duration: Test takes less than 60 minutes: ∼30 min DBS lysis, ∼30 min viral RNA extraction

Duration: Test takes less than 60 minutes: ∼30 min DBS lysis, ∼30 min viral RNA extraction

Avantages de la purification MagMAX par billes magnétiques :

  • Duration: Test takes less than 60 minutes: ∼30 min DBS lysis, ∼30 min viral RNA extraction
  • Beads bind the nucleic acid more efficiently than glass-fiber filters, resulting in higher and more consistent yields
  • Since filters and vacuum manifolds are not used, there is no risk of filter clogging due to cellular particulates in samples
  • This clogging issue is of particular concern with protein-rich, large-volume samples such as whole blood or plasma that are commonly used for viral testing

Kit is designed to recover viral RNA from dried…

Kit is designed to recover viral RNA from dried blood spots (DBS) and plasma for HIV-1 drug resistance testing

MagMAX magnetic-bead technology ensures…

MagMAX magnetic-bead technology ensures reproducible recovery of high-quality HIV-1 viral RNA compatible with downstream applications such as RT-PCR and Sanger sequencing

Automation

Workflows are designed for the KingFisher Flex and KingFisher Duo Prime systems

Sensitivity

Extracts amplifiable viral RNA from DBS and plasma samplesDBS: >2000 copies/mL

Plasma

>1000 copies/mL

Caractéristiques techniques

Général
MarqueApplied Biosystems
Réf. fournisseur (Fisher Scientific)17856501
Caractéristiques
Type de microbillesMagnetic
Méthode de détectionHIV-1 viral RNA compatible with downstream applications such as RT-PCR and Sanger sequencing
Type d’échantillonWhole Blood, Plasma
À utiliser avec (équipement)KingFisher Duo Prime, KingFisher Flex, Magnetic Stand
Nbre de réactions100 reactions
Quantité100 reactions
Stockage et expédition
Contenu et stockage• 60 mL Dried Blood Spots Lysis Solution
• 55 mL Binding Solution
• 100 mL Wash Buffer
• 10 mL Elution Solution
• 1 mL Proteinase K
• 2 mL Total Nucleic Acid Binding Beads

Origine et douane

Réf. fabricantA53770
Pays d’origineÉtats-Unis
Code douanier (SH)3822 19 00 00
Une question, une configuration particulière ?