Invitrogen™ Kit ELISA ZO-1 humain

Réf. : BL-RE-177855Réf. fabricant : EEL211 96 Tests
676,00 € HT

ZO-1 forms complexes with either ZO-2 or ZO-3. In addition, these proteins can also associate with claudin, occludin and F-actin, at tight junction stands, where they provide a linkage between the actin cytoskeleton and the tight junction. ZO-1…

Numéro d’adhésion
Q07157
Plage de dosage
0.16 to 10 ng/mL
Sensibilité du dosage
0.09 ng/mL
Conjugué
HRP
Type de produit
ELISA
Marque
Invitrogen

ZO-1 forms complexes with either ZO-2 or ZO-3. In addition, these proteins can also associate with claudin, occludin and F-actin, at tight junction stands, where they provide a linkage between the actin cytoskeleton and the tight junction. ZO-1…

ZO-1 forms complexes with either ZO-2 or ZO-3. In addition, these proteins can also associate with claudin, occludin and F-actin, at tight junction stands, where they provide a linkage between the actin cytoskeleton and the tight junction. ZO-1 expression is significantly reduced in many breast cancer lines. ZO-2 and ZO-3 are ubiquitously expressed within epithelial tight junctions, and unlike ZO-1, which is also expressed at cell junctions of cardiac myocytes, ZO-2 is not expressed in nonepithelial tissue. ZO-1 is a protein located on a cytoplasmic membrane surface of intercellular tight junctions. ZO-1 may be involved in signal transduction at cell-cell junctions. Two transcript variants encoding distinct isoforms have been identified for the ZO-1 gene. Diseases associated with ZO-1 dysfunction include Celiac Disease and Congenital Nephrotic Syndrome.

Sensibilité

Sensibilité du dosage : 0,09 ng/mL.

Plage de mesure

Plage de dosage : 0,16 à 10 ng/mL.

Durée du dosage

Durée totale du dosage : 3 h. 30 min.

Cible

Cible : ZO-1.

Échantillons

Type d’échantillon : Plasma, Serum (volume Plasma: 100 μL, Serum: 100 μL).

Caractéristiques techniques

Général
MarqueInvitrogen
Réf. fournisseur (Fisher Scientific)30245016
Caractéristiques
Numéro d’adhésionQ07157
Plage de dosage0.16 to 10 ng/mL
Sensibilité du dosage0.09 ng/mL
ConjuguéHRP
Type de produitELISA
Type d’échantillonPlasma, Serum
À utiliser avec (équipement)Colorimetric Microplate Reader
Identification génétique (Entrez)7082
Symbole de gène(s)TJP1
Coefficient de variation inter-dosage<10
Coefficient de variation intra-dosage<10
Contenus des kitsMicro ELISA Plate (Dismountable), Reference Standard, Concentrated Biotinylated Detection Ab(100x), Concentrated HRP Conjugate (100x), Reference Standard & Sample Diluent, Biotinylated Detection Ab Diluent, HRP Conjugate Diluent, Concentrated Wash Buffer(25x), Substrate Reagent, Stop Solution, Plate
Marqueur ou colorantBiotin
Quantité96 Tests
État réglementaireRUO
CibleZO-1
Heure du test1 hr. 20 min.
Caractéristiques physiques
Volume d’échantillonPlasma: 100 μL, Serum: 100 μL
Stockage et expédition
Conditions de stockageRefer to product documentation for component specific storage temperature.
Durée totale du dosage3 hr. 30 min.

Origine et douane

Réf. fabricantEEL211
Pays d’origineChine
Code douanier (SH)3822 19 00 00
Une question, une configuration particulière ?
Contactez-nous pour un devis.