Invitrogen™ Kit ELISA P3NP humain

Réf. : BL-RE-177858Réf. fabricant : EEL204 96 Tests
676,00 € HT

Procollagen type III N-terminal peptide (P3NP) is released as part of collagen synthesis process in muscle. The increase of circulating P3NP is a marker not only of muscle growth, but also of muscle repair and fibrosis. P3NP may be a potential…

Numéro d’adhésion
P02461
Plage de dosage
23.44 to 1500 pg/mL
Sensibilité du dosage
14.06 pg/mL
Conjugué
HRP
Type de produit
ELISA
Marque
Invitrogen

Procollagen type III N-terminal peptide (P3NP) is released as part of collagen synthesis process in muscle. The increase of circulating P3NP is a marker not only of muscle growth, but also of muscle repair and fibrosis. P3NP may be a potential…

Procollagen type III N-terminal peptide (P3NP) is released as part of collagen synthesis process in muscle. The increase of circulating P3NP is a marker not only of muscle growth, but also of muscle repair and fibrosis. P3NP may be a potential biomarker for sarcopenia.

Sensibilité

Sensibilité du dosage : 14,06 pg/mL.

Plage de mesure

Plage de dosage : 23,44 à 1500 pg/mL.

Durée du dosage

Durée totale du dosage : 3 h. 30 min.

Cible

Cible : P3NP.

Échantillons

Type d’échantillon : Plasma, Serum (volume Plasma: 100 μL, Serum: 100 μL).

Caractéristiques techniques

Général
MarqueInvitrogen
Réf. fournisseur (Fisher Scientific)30245241
Caractéristiques
Numéro d’adhésionP02461
Plage de dosage23.44 to 1500 pg/mL
Sensibilité du dosage14.06 pg/mL
ConjuguéHRP
Type de produitELISA
Type d’échantillonPlasma, Serum
À utiliser avec (équipement)Colorimetric Microplate Reader
Identification génétique (Entrez)1281
Symbole de gène(s)COL3A1
Coefficient de variation inter-dosage<10
Coefficient de variation intra-dosage<10
Contenus des kitsMicro ELISA Plate (Dismountable), Reference Standard, Concentrated Biotinylated Detection Ab(100x), Concentrated HRP Conjugate (100x), Reference Standard & Sample Diluent, Biotinylated Detection Ab Diluent, HRP Conjugate Diluent, Concentrated Wash Buffer(25x), Substrate Reagent, Stop Solution, Plate
Marqueur ou colorantBiotin
Quantité96 Tests
État réglementaireRUO
CibleP3NP
Heure du test1 hr. 20 min.
Caractéristiques physiques
Volume d’échantillonPlasma: 100 μL, Serum: 100 μL
Stockage et expédition
Conditions de stockageRefer to product documentation for component specific storage temperature.
Durée totale du dosage3 hr. 30 min.

Origine et douane

Réf. fabricantEEL204
Pays d’origineChine
Code douanier (SH)3822 19 00 00
Une question, une configuration particulière ?
Contactez-nous pour un devis.