Thermo Scientific™ POROS™ CaptureSelect™ GCSF Affinity Column, 4.6 x 50 mm

Réf. : 30484900
3155.00€

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentations broths, or purification intermediates.

Capacité (métrique)
0.8 mL
Matrice
POROS
Contenu et stockage
Column includes EZ grip fittings and column test certificate.
Store at 2–8°C. DO NOT FREEZE.
Volume d’élution max
29 column volumes
Volume d’élution min
14 column volumes
Marque
Thermo Scientific™

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentations broths, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreactor product titers to determine when to harvest or abort a reactor cycle.

POROS CaptureSelect GCSF HPLC columns incorporate the advantages of high-speed POROS chromatography resins with the unique selectivity of CaptureSelect ligands. The combination allows three-minute quantitation of granulocyte colony-stimulating factor (GCSF).

  • Broad utility—POROS A, G, and CaptureSelect affinity ligands address most biological drug classes
  • Rapid—POROS resins offer fast quantitation or purification of immunoglobulins, fusion proteins
  • Hands-off operation—HPLC method can be automated for streamlined operation
  • Robust—allows for high-performance purification over hundreds of chromatography cycles

High Speed with High Specificity

The combination of CaptureSelect GCSF affinity ligand and POROS 20 μm resin provides a high flow rate, high performance chromatography solution for the rapid titer determination and small-scale purification of GCSF.

POROS high performance chromatography allows for the quantitation of product from clarified harvest or partially purified intermediates—typically in under three minutes. Moreover, only minimal sample preparation (0.2 μm filtration) is required, and allows for an eluted product that is highly purified and suitable for further analysis, including mass spectrometry.

Automation

POROS affinity chromatography columns are suitable for use with HPLC systems, which allows for the automation of chromatography methods, data collection, and data analysis. In addition, the immobilized affinity ligands enable one method and buffer system to be used across a class of molecules, streamlining analytical approaches.

Multiple Cycles

Proper sample preparation, adherence to column operating instructions, and the use of an optimized column cleaning regime can result in strong re-use performance. POROS affinity chromatography columns can be cycled hundreds of times for cost-effective and reproducible quantitation or purification.

Capacité (métrique)
0.8 mL
Matrice
POROS
Contenu et stockage
Column includes EZ grip fittings and column test certificate.
Store at 2–8°C. DO NOT FREEZE.
Volume d’élution max
29 column volumes
Volume d’élution min
14 column volumes
À utiliser avec (équipement)
FPLC
Compatibilité à haut débit
Automated Protocols
Pression de fonctionnement max.
2600 psi, 180 bar
Granulométrie
20 μm
Gamme de produits
CaptureSelect™, POROS™
Quantité
1 Column
Cible
Protéine
Type
Colonne
Phase stationnaire
CaptureSelect™ GCSF
Format
Pre-packed Column
Type de colonne
Affinity