The LBP protein is involved in the acute-phase immunologic response to gram-negative bacterial infections. Gram-negative bacteria contain a glycolipid, lipopolysaccharide (LPS), on their outer cell wall. Together with bactericidal…
The LBP protein is involved in the acute-phase immunologic response to gram-negative bacterial infections. Gram-negative bacteria contain a glycolipid, lipopolysaccharide (LPS), on their outer cell wall. Together with bactericidal permeability-increasing protein (BPI), the encoded protein binds LPS and interacts with the CD14 receptor, probably playing a role in regulating LPS-dependent monocyte responses. This protein is part of a family of structurally and functionally related proteins, including BPI, plasma cholesteryl ester transfer protein (CETP), and phospholipid transfer protein (PLTP). Finally, this gene is found on chromosome 20, immediately downstream of the BPI gene.
Sensibilité
Sensibilité du dosage : 1,88 ng/mL.
Plage de mesure
Plage de dosage : 3,13 à 200 ng/mL.
Durée du dosage
Durée totale du dosage : 3 h 30 min.
Échantillons
Type d’échantillon : Plasma (volume 100 µL).
Caractéristiques techniques
| Général |
| Marque | Invitrogen |
| Réf. fournisseur (Fisher Scientific) | 18057374 |
| Caractéristiques |
| Numéro d’adhésion | Q61805 |
| Plage de dosage | 3.13 to 200 ng/mL |
| Sensibilité du dosage | 1.88 ng/mL |
| Conjugué | HRP |
| Type de produit | ELISA |
| Type d’échantillon | Plasma |
| À utiliser avec (équipement) | Colorimetric Microplate Reader |
| Identification génétique (Entrez) | 16803 |
| Symbole de gène(s) | LBP |
| Coefficient de variation inter-dosage | <10% |
| Coefficient de variation intra-dosage | <10% |
| Contenus des kits | Pre-coated 96 well plate, Standard, Biotinylated Detection Antibody, HRP Conjugate, Standard & Sample Diluent, Biotinylated Detection Antibody Diluent, HRP Conjugate Diluent, Wash Buffer, TMB Substrate, Stop Solution, Plate Sealer |
| Marqueur ou colorant | HRP |
| Quantité | 96 Tests |
| État réglementaire | RUO |
| Cible | Mouse |
| Heure du test | 1 hr 20 min |
| Caractéristiques physiques |
| Volume d’échantillon | 100 µL |
| Stockage et expédition |
| Conditions de stockage | Refer to product documentation for component specific storage temperature. |
| Durée totale du dosage | 3 hr 30 min |
Origine et douane
| Réf. fabricant | EEL115 |
|---|
| Pays d’origine | Chine |
|---|
| Code douanier (SH) | 3822 11 00 00 |
|---|
Une question, une configuration particulière ?