Utilizing proximity-based amplification technology, the assay combines the analyte specificity of high-affinity antibody-antigen binding with the signal detection and amplification capabilities of real-time PCR to achieve a simple yet powerful…
Utilizing proximity-based amplification technology, the assay combines the analyte specificity of high-affinity antibody-antigen binding with the signal detection and amplification capabilities of real-time PCR to achieve a simple yet powerful next-generation protein quantitation platform. A user-friendly workflow combined with intuitive software for analytics enables sample-to-answer in just 2 hours.
La troponine I cardiaque (troponine I, TnI, troponine I spécifique au cœur) est une protéine inhibitrice intégrale dans le muscle cardiaque qui existe dans le cadre d’un complexe avec la troponine C (TnC) et la troponine T (TnT). La sous-unité TnT de la troponine se lie à la forme tropomyosine-t, un complexe troponine-tropomyosine, ancré en place par la liaison de TnI à l’actine, à l’intérieur de filaments minces musculaires. Le changement structurel résultant de la liaison du calcium à des sites spécifiques de la sous-unité TnC réglementaire libère la région inhibitrice de TnI de l’actine, ce qui permet l’adhérence de la myosine de la protéine moteur moléculaire, ce qui permet une contraction musculaire et donc le mouvement. Les mesures des taux de TnI et de TnT dans le sang sont un indicateur diagnostique important des lésions musculaires cardiaques et peuvent être utilisées pour différencier l’angine et l’infarctus du myocarde chez les patients souffrant de douleurs thoraciques. La troponine I cardiaque inhibe également l’angiogenèse in vivo et in vitro. Les mutations du gène de troponine I cardiaque provoquent une cardiomyopathie hypertrophique familiale de type 7 (CMH7) et une cardiomyopathie restrictive familiale (RCM).
High sensitivity-detect low levels of protein…
High sensitivity-detect low levels of protein with greater sensitivity than traditional methods
Broad dynamic range-≥5 logarithmic units…
Broad dynamic range-≥5 logarithmic units, minimizing sample dilutions to ensure they fall within the range
Small sample consumption-use 2–5 μL of sample…
Small sample consumption-use 2–5 μL of sample (compared to 75 μL for triplicate wells with other methods)
Fast, easy workflow-2 hours from sample to…
Fast, easy workflow-2 hours from sample to answer, with no wash steps
No proprietary instrument to purchase-runs on any…
No proprietary instrument to purchase-runs on any real-time PCR instrument
Caractéristiques techniques
| Général |
| Marque | Invitrogen |
| Réf. fournisseur (Fisher Scientific) | 17195772 |
| Caractéristiques |
| Numéro d’adhésion | Troponine I cardiaque ; isoforme de la troponine I cardiaque ; cardiomyopathie, dilatée 2 A (récessive autosomique) ; CMD1FF ; CMD2A ; CMH7 ; cTNI ; MGC116817 ; RCM1 ; Tn1 ; TnI ; TNNC1 ; Tnni3 ; TPN1 ; troponine 1, type 3 ; troponine I type 3 (cardiaque) ; troponine I, cardiaque 3 ; troponine I, mu |
| Plage de dosage | 0,32 à 25 000 pg/ml |
| Sensibilité du dosage | <0,3 pg |
| Type de produit | ELISA |
| Type d’échantillon | Plasma, Sérum, Surnageant |
| À utiliser avec (équipement) | Instruments qPCR |
| Identification génétique (Entrez) | P19429 |
| Symbole de gène(s) | TNNI3 |
| Contenus des kits | Tampon de dilution d’essai Antibody-Conjugate Antibody-Conjugate B Tampon de dilution antibody-Conjugate Standard Master Mix ligase |
| Quantité | 96 tests |
| État réglementaire | Usage exclusivement réservé à la recherche |
| Cible | Troponine I cardiaque |
| Heure du test | 30 min |
| Caractéristiques physiques |
| Volume d’échantillon | Sérum, 2 à 5 µl ; plasma, 2 à 5 µl ; surnageant, 2 à 5 µl |
| Stockage et expédition |
| Conditions de stockage | -20°C |
| Durée totale du dosage | 2 h |
Origine et douane
| Réf. fabricant | A46074 |
|---|
| Pays d’origine | États-Unis |
|---|
| Code douanier (SH) | 2530 20 00 00 |
|---|
Une question, une configuration particulière ?