Invitrogen™ Kit ELISA E-Cadherin (CDH1) humain
For the quantitative detection of Human E-Cadherin (CDH1)
- Numéro d’adhésion
- P12830
- Plage de dosage
- 0.16 to 10 ng/mL
- Sensibilité du dosage
- 0.1 ng/mL
- Conjugué
- HRP
- Type de produit
- ELISA
- Marque
- Invitrogen
"/>
For the quantitative detection of Human E-Cadherin (CDH1)
E-Cadherin (epithelial cadherin) is a classical cadherin from the cadherin (alcium dependent adhesion protein) superfamily. The encoded protein is a calcium dependent cell-cell adhesion glycoprotein comprised of five extracellular cadherin repeats, a transmembrane region and a highly conserved cytoplasmic tail. Mutations in this gene are correlated with gastric, breast, colorectal, thyroid and ovarian cancer. Loss of function is thought to contribute to progression in cancer by increasing proliferation, invasion, and/or metastasis. The ectodomain of this protein mediates bacterial adhesion to mammalian cells and the cytoplasmic domain is required for internalization. Identified transcript variants arise from mutation at consensus splice sites. E-cadherin plays a central role in the growth and development of cells by controlling tissue architecture, and maintenance of tissue integrity. In humans, E-cadherin is encoded by the CDH1 gene present on chromosome 16. Studies have demonstrated that reduction and/or loss of E-cadherin expression in carcinomas correlates positively with the potential of these tumors for invasion and metastasis.
| Marque | Invitrogen |
|---|---|
| Réf. B-LABO | BL-RE-092389 |
| Réf. fabricant | 18037424 |
| Numéro d’adhésion | P12830 |
| Plage de dosage | 0.16 to 10 ng/mL |
| Sensibilité du dosage | 0.1 ng/mL |
| Conjugué | HRP |
| Type de produit | ELISA |
| Type d’échantillon | Plasma |
| À utiliser avec (équipement) | Colorimetric Microplate Reader |
| Identification génétique (Entrez) | 999 |
| Symbole de gène(s) | CDH1 |
| Coefficient de variation inter-dosage | <10% |
| Coefficient de variation intra-dosage | <10% |
| Contenus des kits | Pre-coated 96 well plate, Standard, Biotinylated Detection Antibody, HRP Conjugate, Standard & Sample Diluent, Biotinylated Detection Antibody Diluent, HRP Conjugate Diluent, Wash Buffer, TMB Substrate, Stop Solution, Plate Sealer |
| Marqueur ou colorant | HRP |
| Quantité | 96 Tests |
| État réglementaire | RUO |
| Volume d’échantillon | 100 µL |
| Conditions de stockage | Refer to product documentation for component specific storage temperature. |
| Cible | Human |
| Heure du test | 1 hr 20 min |
| Durée totale du dosage | 3 hr 30 min |