The Triglyceride (TG) Colormetric Assay Kit is a highly reliable and sensitive assay designed for the quantitative measurement of triglycerides in serum, plasma, and tissue samples. Triglycerides are a type of lipid molecule that play a crucial role…
The Triglyceride (TG) Colormetric Assay Kit is a highly reliable and sensitive assay designed for the quantitative measurement of triglycerides in serum, plasma, and tissue samples. Triglycerides are a type of lipid molecule that play a crucial role in energy storage and metabolism. They are the main component of vegetable oil, animal fat, low-density lipoprotein (LDL), and very low-density lipoprotein (VLDL). Elevated levels of triglycerides in the blood have been associated with an increased risk of cardiovascular disease, glucose metabolism, insulin resistance, and Type 2 diabetes.
The assay utilizes the GPO-PAP method, which involves the hydrolysis of triglycerides to glycerol and fatty acids. Glycerol is then oxidized by glycerol kinase to glycerol-3-phosphate, which is oxidized by GPO and produces hydrogen peroxide. In the presence of 4-aminoantipyrine and phenol, hydrogen peroxide is catalyzed by peroxidase (POD) to produce colored quinones which can be measured at 510 nm to calculate the amount of TG in the sample.
• Simple and fast protocol—user-friendly, requiring minimal hands-on time and providing rapid results within a short incubation period
• Broad range of kits—across key analytes and targets within the most important metabolic pathways
• Consistent—strict quality control criteria to ensure reproducible and reliable results
Sensibilité
Sensibilité du dosage : 0,14 mmol/L.
Plage de mesure
Plage de dosage : 0,14–10 mmol/L.
Durée du dosage
Durée totale du dosage : 30 min.
Reproductibilité
Coefficient de variation intra-dosage 4,1, inter-dosage 9,2.
Échantillons
Volume d’échantillon : 2,5 μL.
Caractéristiques techniques
| Général |
| Marque | Invitrogen |
| Réf. fournisseur (Fisher Scientific) | 17972071 |
| Caractéristiques |
| Plage de dosage | 0.14–10 mmol/L |
| Sensibilité du dosage | 0.14 mmol/L |
| Méthode de détection | Colorimetric |
| Type d’échantillon | Plasma, Serum, Tissue Homogenates, Whole Cells |
| À utiliser avec (équipement) | Microplate Reader |
| Temps d’incubation | 10 min. |
| Coefficient de variation inter-dosage | 9.2 |
| Coefficient de variation intra-dosage | 4.1 |
| Kit cible nommé | Triglyceride (TG) |
| Caractéristiques physiques |
| Volume d’échantillon | 2.5 μL |
| Stockage et expédition |
| Contenu et stockage | Store at 2–8°C.
|
| Conditions d’expédition | Dry Ice, 2–8°C |
| Durée totale du dosage | 30 min. |
Origine et douane
| Réf. fabricant | EEA028 |
|---|
| Pays d’origine | Chine |
|---|
| Code douanier (SH) | 3822 11 00 00 |
|---|
Une question, une configuration particulière ?