This gene encodes the acidic form of complement factor 4, part of the classical activation pathway. The protein is expressed as a single chain precursor which is proteolytically cleaved into a trimer of alpha, beta, and gamma chains prior to…
This gene encodes the acidic form of complement factor 4, part of the classical activation pathway. The protein is expressed as a single chain precursor which is proteolytically cleaved into a trimer of alpha, beta, and gamma chains prior to secretion. The trimer provides a surface for interaction between the antigen-antibody complex and other complement components. The alpha chain may be cleaved to release C4 anaphylatoxin, a mediator of local inflammation. Deficiency of this protein is associated with systemic lupus erythematosus and type I diabetes mellitus. This gene localizes to the major histocompatibility complex (MHC) class III region on chromosome 6. Varying haplotypes of this gene cluster exist, such that individuals may have 1, 2, or 3 copies of this gene.
Sensibilité
Sensibilité du dosage : 1,88 ng/mL.
Plage de mesure
Plage de dosage : 3,13 à 200 ng/mL.
Durée du dosage
Durée totale du dosage : 3 h 30 min.
Échantillons
Type d’échantillon : Plasma (volume 100 µL).
Caractéristiques techniques
| Général |
| Marque | Invitrogen |
| Réf. fournisseur (Fisher Scientific) | 18017444 |
| Caractéristiques |
| Numéro d’adhésion | P0C0L4, P0C0L5 |
| Plage de dosage | 3.13 to 200 ng/mL |
| Sensibilité du dosage | 1.88 ng/mL |
| Conjugué | HRP |
| Type de produit | ELISA |
| Type d’échantillon | Plasma |
| À utiliser avec (équipement) | Colorimetric Microplate Reader |
| Identification génétique (Entrez) | 720, 721 |
| Symbole de gène(s) | C4A, C4B |
| Coefficient de variation inter-dosage | <10% |
| Coefficient de variation intra-dosage | <10% |
| Contenus des kits | Pre-coated 96 well plate, Standard, Biotinylated Detection Antibody, HRP Conjugate, Standard & Sample Diluent, Biotinylated Detection Antibody Diluent, HRP Conjugate Diluent, Wash Buffer, TMB Substrate, Stop Solution, Plate Sealer |
| Marqueur ou colorant | HRP |
| Quantité | 96 Tests |
| État réglementaire | RUO |
| Cible | Human |
| Heure du test | 1 hr 20 min |
| Caractéristiques physiques |
| Volume d’échantillon | 100 µL |
| Stockage et expédition |
| Conditions de stockage | Refer to product documentation for component specific storage temperature. |
| Durée totale du dosage | 3 hr 30 min |
Origine et douane
| Réf. fabricant | EEL075 |
|---|
| Pays d’origine | Chine |
|---|
| Code douanier (SH) | 3822 11 00 00 |
|---|
Une question, une configuration particulière ?