The human alpha globin gene cluster located on chromosome 16 spans about 30 kb and includes seven loci: 5'- zeta - pseudozeta - mu - pseudoalpha-1 - alpha-2 - alpha-1 - theta - 3'. The alpha-2 (HBA2) and alpha-1 (HBA1) coding sequences are…
The human alpha globin gene cluster located on chromosome 16 spans about 30 kb and includes seven loci: 5'- zeta - pseudozeta - mu - pseudoalpha-1 - alpha-2 - alpha-1 - theta - 3'. The alpha-2 (HBA2) and alpha-1 (HBA1) coding sequences are identical. These genes differ slightly over the 5' untranslated regions and the introns, but they differ significantly over the 3' untranslated regions. Two alpha chains plus two beta chains constitute HbA, which in normal adult life comprises about 97% of the total hemoglobin; alpha chains combine with delta chains to constitute HbA-2, which with HbF (fetal hemoglobin) makes up the remaining 3% of adult hemoglobin. Alpha thalassemias result from deletions of each of the alpha genes as well as deletions of both HBA2 and HBA1; some nondeletion alpha thalassemias have also been reported.
Sensibilité
Sensibilité du dosage : 93,75 ng/mL.
Plage de mesure
Plage de dosage : 156,25 à 10000 ng/mL.
Durée du dosage
Durée totale du dosage : 3 h 30 min.
Échantillons
Type d’échantillon : Plasma (volume 100 µL).
Caractéristiques techniques
| Général |
| Marque | Invitrogen |
| Réf. fournisseur (Fisher Scientific) | 18047384 |
| Caractéristiques |
| Plage de dosage | 156.25 to 10000 ng/mL |
| Sensibilité du dosage | 93.75 ng/mL |
| Conjugué | HRP |
| Type de produit | ELISA |
| Type d’échantillon | Plasma |
| À utiliser avec (équipement) | Colorimetric Microplate Reader |
| Coefficient de variation inter-dosage | <10% |
| Coefficient de variation intra-dosage | <10% |
| Contenus des kits | Pre-coated 96 well plate, Standard, Biotinylated Detection Antibody, HRP Conjugate, Standard & Sample Diluent, Biotinylated Detection Antibody Diluent, HRP Conjugate Diluent, Wash Buffer, TMB Substrate, Stop Solution, Plate Sealer |
| Marqueur ou colorant | HRP |
| Quantité | 96 Tests |
| État réglementaire | RUO |
| Cible | Mouse |
| Heure du test | 1 hr 20 min |
| Caractéristiques physiques |
| Volume d’échantillon | 100 µL |
| Stockage et expédition |
| Conditions de stockage | Refer to product documentation for component specific storage temperature. |
| Durée totale du dosage | 3 hr 30 min |
Origine et douane
| Réf. fabricant | EEL118 |
|---|
| Pays d’origine | Chine |
|---|
| Code douanier (SH) | 3822 11 00 00 |
|---|
Une question, une configuration particulière ?