Invitrogen™ Kit ELISA GAD67 humain

Réf. : BL-RE-093667Réf. fabricant : EEL065 96 Tests
694,00 € HT

GAD-65 and GAD-67 are members of the group II decarboxylase family of proteins and are responsible for catalyzing the rate limiting step in the production of GABA (gamma-aminobutyric acid) from L-glutamic acid. Although both GADs are found in the…

Numéro d’adhésion
Q99259
Plage de dosage
1.56 to 100 ng/mL
Sensibilité du dosage
0.94 ng/mL
Conjugué
HRP
Type de produit
ELISA
Marque
Invitrogen

GAD-65 and GAD-67 are members of the group II decarboxylase family of proteins and are responsible for catalyzing the rate limiting step in the production of GABA (gamma-aminobutyric acid) from L-glutamic acid. Although both GADs are found in the…

GAD-65 and GAD-67 are members of the group II decarboxylase family of proteins and are responsible for catalyzing the rate limiting step in the production of GABA (gamma-aminobutyric acid) from L-glutamic acid. Although both GADs are found in the brain, GAD-65 localizes to synaptic vesicle membranes in nerve terminals, while GAD-67 is distributed throughout the cell. GAD-67 is responsible for the basal levels of GABA synthesis. In the case of a heightened demand for GABA in neurotransmission, GAD-65 will transiently activate to assist in GABA production. The loss of GAD-65 is detrimental and can impair GABA neurotransmission, however the loss of GAD-67 is lethal. Due to alternative splicing, two isoforms exist for GAD-67: the predominant GAD-67 form and the minor GAD-25 form.

Sensibilité

Sensibilité du dosage : 0,94 ng/mL.

Plage de mesure

Plage de dosage : 1,56 à 100 ng/mL.

Durée du dosage

Durée totale du dosage : 3 h 30 min.

Échantillons

Type d’échantillon : Plasma (volume 100 µL).

Conjugué

Conjugué : HRP.

Caractéristiques techniques

Général
MarqueInvitrogen
Réf. fournisseur (Fisher Scientific)18077384
Caractéristiques
Numéro d’adhésionQ99259
Plage de dosage1.56 to 100 ng/mL
Sensibilité du dosage0.94 ng/mL
ConjuguéHRP
Type de produitELISA
Type d’échantillonPlasma
À utiliser avec (équipement)Colorimetric Microplate Reader
Identification génétique (Entrez)2571
Symbole de gène(s)GAD1
Coefficient de variation inter-dosage<10%
Coefficient de variation intra-dosage<10%
Contenus des kitsPre-coated 96 well plate, Standard, Biotinylated Detection Antibody, HRP Conjugate, Standard & Sample Diluent, Biotinylated Detection Antibody Diluent, HRP Conjugate Diluent, Wash Buffer, TMB Substrate, Stop Solution, Plate Sealer
Marqueur ou colorantHRP
Quantité96 Tests
État réglementaireRUO
CibleHuman
Heure du test1 hr 20 min
Caractéristiques physiques
Volume d’échantillon100 µL
Stockage et expédition
Conditions de stockageRefer to product documentation for component specific storage temperature.
Durée totale du dosage3 hr 30 min

Origine et douane

Réf. fabricantEEL065
Pays d’origineChine
Code douanier (SH)3822 11 00 00
Une question, une configuration particulière ?